Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Pencahayaan bilik bersih dan peralatan elektrik

Saluran elektrik bilik bersih

A smooth enclosed cable route using sealed tube, couplings and penetration fittings for exposed cleanroom electrical services.
  • Smooth Enclosed Cable Route
  • Sealed Compression Couplings
  • Hygienic Support Clips
  • Gasketed Wall Penetrations
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.

Ciri-ciri Utama

The closed tube protects cables and removes loose bundles from the cleaning surface.

Compression or threaded couplings maintain continuity through each straight joint.

Swept bends reduce pulling stress on control and power conductors.

Smooth support clips avoid deep saddles and exposed sharp threads.

Sealed bulkhead fittings close the wall around each conduit penetration.

Kebimbangan Produk Pelanggan

An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.

Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.

Permohonan yang biasa

Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings

Parameter teknikal

Typical configurable construction ranges for cleanroom electrical conduit are listed below.

Bahan TerasSUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals
Ketebalan Panel1.0-2.0 mm conduit wall thickness
Lebar berkesan16-63 mm nominal conduit diameter
Panjang maksimumUp to 6000 mm per straight tube section
Keluli Menghadapi Ketebalan1.0-2.0 mm stainless or steel tube wall
Ketumpatan terasApproximately 7900-8000 kg/m³ for stainless conduit material
Kekonduksian Terma14-16 W/(m·K) for stainless tube
Kemasan permukaanFine-brushed, electropolished or smooth white-coated exterior
Jenis BersatuThreaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads

Planning a Cleanroom Electrical Conduit specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat