Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Reinraum Beleuchtung und elektrische Ausrüstung

Cleanroom elektrische Leitung

A smooth enclosed cable route using sealed tube, couplings and penetration fittings for exposed cleanroom electrical services.
  • Smooth Enclosed Cable Route
  • Sealed Compression Couplings
  • Hygienic Support Clips
  • Gasketed Wall Penetrations

Produkteinführung

Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.

Key Features

The closed tube protects cables and removes loose bundles from the cleaning surface.

Compression or threaded couplings maintain continuity through each straight joint.

Swept bends reduce pulling stress on control and power conductors.

Smooth support clips avoid deep saddles and exposed sharp threads.

Sealed bulkhead fittings close the wall around each conduit penetration.

Kunden Produktbedenken

An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.

Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.

Typische Anwendungen

Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings

Technische Parameter

Typical configurable construction ranges for cleanroom electrical conduit are listed below.

Core MaterialSUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals
Panel Dicke1.0-2.0 mm conduit wall thickness
Effektive Breite16-63 mm nominal conduit diameter
Maximale LängeUp to 6000 mm per straight tube section
Stahl facing Dicke1.0-2.0 mm stainless or steel tube wall
KerndichteApproximately 7900-8000 kg/m³ for stainless conduit material
Thermische Leitfähigkeit14-16 W/(m·K) for stainless tube
Oberfläche FinishFine-brushed, electropolished or smooth white-coated exterior
Gemeinsamer TypThreaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads

Planning a Cleanroom Electrical Conduit specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt