Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Iluminación de sala limpia y equipos eléctricos

Conductor eléctrico de sala limpia

A smooth enclosed cable route using sealed tube, couplings and penetration fittings for exposed cleanroom electrical services.
  • Smooth Enclosed Cable Route
  • Sealed Compression Couplings
  • Hygienic Support Clips
  • Gasketed Wall Penetrations
Solicite un presupuesto. Browse productos

Introducción del producto

Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.

Características clave

The closed tube protects cables and removes loose bundles from the cleaning surface.

Compression or threaded couplings maintain continuity through each straight joint.

Swept bends reduce pulling stress on control and power conductors.

Smooth support clips avoid deep saddles and exposed sharp threads.

Sealed bulkhead fittings close the wall around each conduit penetration.

Preocupaciones del producto del cliente

An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.

Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.

Aplicaciones típicas

Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings

Parámetros técnicos

Typical configurable construction ranges for cleanroom electrical conduit are listed below.

Materiales CoreSUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals
Panel de espesor1.0-2.0 mm conduit wall thickness
Ancho efectivo16-63 mm nominal conduit diameter
Longitud máximaUp to 6000 mm per straight tube section
Acero frente a espesor1.0-2.0 mm stainless or steel tube wall
Densidad CoreApproximately 7900-8000 kg/m³ for stainless conduit material
Conductividad térmica14-16 W/(m·K) for stainless tube
Superficie acabadaFine-brushed, electropolished or smooth white-coated exterior
Tipo conjuntoThreaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads

Planning a Cleanroom Electrical Conduit specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto