الألومنيوم أنبوب الهواء

A lightweight aluminum sheet duct for clean, non-abrasive air systems where corrosion resistance and reduced suspended load are important.
  • Low Structural Weight
  • Natural Corrosion Resistance
  • Clean Smooth Interior
  • Rectangular or Round Format
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

Aluminum ductwork reduces the dead load carried by cleanroom ceiling supports while providing a naturally corrosion-resistant surface for conditioned air. Sections are fabricated from 3003 or 5052 aluminum sheet using lock-formed or welded seams and aluminum flange components. Because aluminum is softer than steel, panel reinforcement and support spacing are selected to prevent distortion during transport and operation. The non-sparking, non-ferrous construction is useful in selected technical areas, provided the conveyed chemicals and galvanic interfaces are compatible with the chosen alloy.

الخصائص الرئيسية

Low sheet density reduces handling effort and the permanent load on overhead support systems.

A stable aluminum oxide layer protects the surface in normal indoor clean-air service.

Non-ferrous construction avoids rust staining from exposed cut edges.

Formed stiffeners and closer hanger spacing control deformation in broad rectangular panels.

مخاوف المنتج للعملاء

Lightweight aluminum duct must be detailed around its lower stiffness, dissimilar-metal contacts and the actual chemical exposure of the air stream.

A steel duct route places excessive load on a long-span cleanroom ceiling.Aluminum sheet lowers duct mass while maintaining the scheduled internal dimensions.
Soft panels dent during lifting and field assembly.Protective packaging, reinforced faces and controlled lifting points maintain the duct geometry.
Direct contact with steel hangers causes galvanic staining in humid areas.Non-conductive isolation pads and compatible fasteners separate dissimilar metals.
A selected cleaning agent dulls or pits the aluminum finish.Alloy and surface treatment are matched to the documented chemical and cleaning exposure.

تطبيقات نموذجية

Cleanroom supply-air branchesLightweight ceiling duct routesHumidity-controlled production roomsMarine or coastal technical areasNon-ferrous ventilation assemblies

المعلمات الفنية

Common construction ranges for fabricated aluminum air duct are summarized below.

المواد الأساسية3003-H14 or 5052-H32 aluminum alloy sheet
سمك اللوحة0.8–1.8 mm, selected by duct dimension and pressure duty
العرض الفعال150–1600 mm rectangular side dimension
الحد الأقصى الطول1200–1500 mm per fabricated section
الصلب يواجه سمك0.8–1.8 mm aluminum wall in place of steel facing
الكثافة الأساسيةApproximately 2700 kg/m³ solid aluminum construction
الموصلية الحراريةApproximately 138–170 W/(m·K), depending on aluminum alloy
إنهاء السطحMill finish, clear anodized or powder-coated aluminum
نوع المشتركAluminum flange or slip joint with compatible gasket and isolated fasteners
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

3003 or 5052 alloyClear anodized or powder-coated finishRectangular, round and transition sectionsInternal acoustic or external thermal insulation