Saluran udara aluminium

A lightweight aluminum sheet duct for clean, non-abrasive air systems where corrosion resistance and reduced suspended load are important.
  • Low Structural Weight
  • Natural Corrosion Resistance
  • Clean Smooth Interior
  • Rectangular or Round Format
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

Aluminum ductwork reduces the dead load carried by cleanroom ceiling supports while providing a naturally corrosion-resistant surface for conditioned air. Sections are fabricated from 3003 or 5052 aluminum sheet using lock-formed or welded seams and aluminum flange components. Because aluminum is softer than steel, panel reinforcement and support spacing are selected to prevent distortion during transport and operation. The non-sparking, non-ferrous construction is useful in selected technical areas, provided the conveyed chemicals and galvanic interfaces are compatible with the chosen alloy.

Ciri-ciri Utama

Low sheet density reduces handling effort and the permanent load on overhead support systems.

A stable aluminum oxide layer protects the surface in normal indoor clean-air service.

Non-ferrous construction avoids rust staining from exposed cut edges.

Formed stiffeners and closer hanger spacing control deformation in broad rectangular panels.

Kebimbangan Produk Pelanggan

Lightweight aluminum duct must be detailed around its lower stiffness, dissimilar-metal contacts and the actual chemical exposure of the air stream.

A steel duct route places excessive load on a long-span cleanroom ceiling.Aluminum sheet lowers duct mass while maintaining the scheduled internal dimensions.
Soft panels dent during lifting and field assembly.Protective packaging, reinforced faces and controlled lifting points maintain the duct geometry.
Direct contact with steel hangers causes galvanic staining in humid areas.Non-conductive isolation pads and compatible fasteners separate dissimilar metals.
A selected cleaning agent dulls or pits the aluminum finish.Alloy and surface treatment are matched to the documented chemical and cleaning exposure.

Permohonan yang biasa

Cleanroom supply-air branchesLightweight ceiling duct routesHumidity-controlled production roomsMarine or coastal technical areasNon-ferrous ventilation assemblies

Parameter teknikal

Common construction ranges for fabricated aluminum air duct are summarized below.

Bahan Teras3003-H14 or 5052-H32 aluminum alloy sheet
Ketebalan Panel0.8–1.8 mm, selected by duct dimension and pressure duty
Lebar berkesan150–1600 mm rectangular side dimension
Panjang maksimum1200–1500 mm per fabricated section
Keluli Menghadapi Ketebalan0.8–1.8 mm aluminum wall in place of steel facing
Ketumpatan terasApproximately 2700 kg/m³ solid aluminum construction
Kekonduksian TermaApproximately 138–170 W/(m·K), depending on aluminum alloy
Kemasan permukaanMill finish, clear anodized or powder-coated aluminum
Jenis BersatuAluminum flange or slip joint with compatible gasket and isolated fasteners
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

3003 or 5052 alloyClear anodized or powder-coated finishRectangular, round and transition sectionsInternal acoustic or external thermal insulation

Planning a Aluminum Air Duct specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami