Sistem Distribusi Udara Cleanroom

Saluran Udara Aluminium Aluminium

A lightweight aluminum sheet duct for clean, non-abrasive air systems where corrosion resistance and reduced suspended load are important.
  • Low Structural Weight
  • Natural Corrosion Resistance
  • Clean Smooth Interior
  • Rectangular or Round Format
Permintaan untuk kutipan Browse Produk

Perkenalan produk

Aluminum ductwork reduces the dead load carried by cleanroom ceiling supports while providing a naturally corrosion-resistant surface for conditioned air. Sections are fabricated from 3003 or 5052 aluminum sheet using lock-formed or welded seams and aluminum flange components. Because aluminum is softer than steel, panel reinforcement and support spacing are selected to prevent distortion during transport and operation. The non-sparking, non-ferrous construction is useful in selected technical areas, provided the conveyed chemicals and galvanic interfaces are compatible with the chosen alloy.

Fitur utama:

Low sheet density reduces handling effort and the permanent load on overhead support systems.

A stable aluminum oxide layer protects the surface in normal indoor clean-air service.

Non-ferrous construction avoids rust staining from exposed cut edges.

Formed stiffeners and closer hanger spacing control deformation in broad rectangular panels.

Kekhawatiran produk pelanggan

Lightweight aluminum duct must be detailed around its lower stiffness, dissimilar-metal contacts and the actual chemical exposure of the air stream.

A steel duct route places excessive load on a long-span cleanroom ceiling.Aluminum sheet lowers duct mass while maintaining the scheduled internal dimensions.
Soft panels dent during lifting and field assembly.Protective packaging, reinforced faces and controlled lifting points maintain the duct geometry.
Direct contact with steel hangers causes galvanic staining in humid areas.Non-conductive isolation pads and compatible fasteners separate dissimilar metals.
A selected cleaning agent dulls or pits the aluminum finish.Alloy and surface treatment are matched to the documented chemical and cleaning exposure.

Aplikasi yang Tipis

Cleanroom supply-air branchesLightweight ceiling duct routesHumidity-controlled production roomsMarine or coastal technical areasNon-ferrous ventilation assemblies

Parameter teknis

Common construction ranges for fabricated aluminum air duct are summarized below.

Bahan inti3003-H14 or 5052-H32 aluminum alloy sheet
Ketebalan Panel (Panel Thickness)0.8–1.8 mm, selected by duct dimension and pressure duty
Efektif lebar150–1600 mm rectangular side dimension
Panjang maksimum1200–1500 mm per fabricated section
Baja menghadap ketebalan0.8–1.8 mm aluminum wall in place of steel facing
Kepadatan inti (core density)Approximately 2700 kg/m³ solid aluminum construction
Konduktivitas Termal (Thermal Conductivity)Approximately 138–170 W/(m·K), depending on aluminum alloy
Permukaan selesaiMill finish, clear anodized or powder-coated aluminum
Jenis BersamaAluminum flange or slip joint with compatible gasket and isolated fasteners
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

3003 or 5052 alloyJelas anodized atau bubuk-dilapisi selesaiRectangular, round and transition sectionsInternal acoustic or external thermal insulation