Systèmes de distribution d'air Cleanroom

Duct d'air en aluminium

A lightweight aluminum sheet duct for clean, non-abrasive air systems where corrosion resistance and reduced suspended load are important.
  • Low Structural Weight
  • Natural Corrosion Resistance
  • Clean Smooth Interior
  • Rectangular or Round Format
Demander un devis. Browse les produits

Introduction de produit

Aluminum ductwork reduces the dead load carried by cleanroom ceiling supports while providing a naturally corrosion-resistant surface for conditioned air. Sections are fabricated from 3003 or 5052 aluminum sheet using lock-formed or welded seams and aluminum flange components. Because aluminum is softer than steel, panel reinforcement and support spacing are selected to prevent distortion during transport and operation. The non-sparking, non-ferrous construction is useful in selected technical areas, provided the conveyed chemicals and galvanic interfaces are compatible with the chosen alloy.

Key Features

Low sheet density reduces handling effort and the permanent load on overhead support systems.

A stable aluminum oxide layer protects the surface in normal indoor clean-air service.

Non-ferrous construction avoids rust staining from exposed cut edges.

Formed stiffeners and closer hanger spacing control deformation in broad rectangular panels.

Préoccupations du client produit

Lightweight aluminum duct must be detailed around its lower stiffness, dissimilar-metal contacts and the actual chemical exposure of the air stream.

A steel duct route places excessive load on a long-span cleanroom ceiling.Aluminum sheet lowers duct mass while maintaining the scheduled internal dimensions.
Soft panels dent during lifting and field assembly.Protective packaging, reinforced faces and controlled lifting points maintain the duct geometry.
Direct contact with steel hangers causes galvanic staining in humid areas.Non-conductive isolation pads and compatible fasteners separate dissimilar metals.
A selected cleaning agent dulls or pits the aluminum finish.Alloy and surface treatment are matched to the documented chemical and cleaning exposure.

Les applications typiques

Cleanroom supply-air branchesLightweight ceiling duct routesHumidity-controlled production roomsMarine or coastal technical areasNon-ferrous ventilation assemblies

Paramètres techniques

Common construction ranges for fabricated aluminum air duct are summarized below.

Matériaux de base3003-H14 or 5052-H32 aluminum alloy sheet
Panneau épaisseur0.8–1.8 mm, selected by duct dimension and pressure duty
Largeur effective150–1600 mm rectangular side dimension
Longueur maximale1200–1500 mm per fabricated section
Acier face épaisseur0.8–1.8 mm aluminum wall in place of steel facing
Densité CoreApproximately 2700 kg/m³ solid aluminum construction
Conductivité thermiqueApproximately 138–170 W/(m·K), depending on aluminum alloy
surface finieMill finish, clear anodized or powder-coated aluminum
Type jointAluminum flange or slip joint with compatible gasket and isolated fasteners
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

3003 or 5052 alloyClear anodized or powder-coated finishRectangular, round and transition sectionsInternal acoustic or external thermal insulation