Sistemas de distribución de aire para salas limpias

Ducto de aire de aluminio

A lightweight aluminum sheet duct for clean, non-abrasive air systems where corrosion resistance and reduced suspended load are important.
  • Low Structural Weight
  • Natural Corrosion Resistance
  • Clean Smooth Interior
  • Rectangular or Round Format
Solicite un presupuesto. Browse productos

Introducción del producto

Aluminum ductwork reduces the dead load carried by cleanroom ceiling supports while providing a naturally corrosion-resistant surface for conditioned air. Sections are fabricated from 3003 or 5052 aluminum sheet using lock-formed or welded seams and aluminum flange components. Because aluminum is softer than steel, panel reinforcement and support spacing are selected to prevent distortion during transport and operation. The non-sparking, non-ferrous construction is useful in selected technical areas, provided the conveyed chemicals and galvanic interfaces are compatible with the chosen alloy.

Características clave

Low sheet density reduces handling effort and the permanent load on overhead support systems.

A stable aluminum oxide layer protects the surface in normal indoor clean-air service.

Non-ferrous construction avoids rust staining from exposed cut edges.

Formed stiffeners and closer hanger spacing control deformation in broad rectangular panels.

Preocupaciones del producto del cliente

Lightweight aluminum duct must be detailed around its lower stiffness, dissimilar-metal contacts and the actual chemical exposure of the air stream.

A steel duct route places excessive load on a long-span cleanroom ceiling.Aluminum sheet lowers duct mass while maintaining the scheduled internal dimensions.
Soft panels dent during lifting and field assembly.Protective packaging, reinforced faces and controlled lifting points maintain the duct geometry.
Direct contact with steel hangers causes galvanic staining in humid areas.Non-conductive isolation pads and compatible fasteners separate dissimilar metals.
A selected cleaning agent dulls or pits the aluminum finish.Alloy and surface treatment are matched to the documented chemical and cleaning exposure.

Aplicaciones típicas

Cleanroom supply-air branchesLightweight ceiling duct routesHumidity-controlled production roomsMarine or coastal technical areasNon-ferrous ventilation assemblies

Parámetros técnicos

Common construction ranges for fabricated aluminum air duct are summarized below.

Materiales Core3003-H14 or 5052-H32 aluminum alloy sheet
Panel de espesor0.8–1.8 mm, selected by duct dimension and pressure duty
Ancho efectivo150–1600 mm rectangular side dimension
Longitud máxima1200–1500 mm per fabricated section
Acero frente a espesor0.8–1.8 mm aluminum wall in place of steel facing
Densidad CoreApproximately 2700 kg/m³ solid aluminum construction
Conductividad térmicaApproximately 138–170 W/(m·K), depending on aluminum alloy
Superficie acabadaMill finish, clear anodized or powder-coated aluminum
Tipo conjuntoAluminum flange or slip joint with compatible gasket and isolated fasteners
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

3003 or 5052 alloyClear anodized or powder-coated finishRectangular, round and transition sectionsInternal acoustic or external thermal insulation