Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Персонал и оборудование для дезактивации материалов

Химический защитный костюм для деконтаминации

A protective-suit treatment chamber that doses a compatible solution into a controlled spray cycle followed by a separate rinse.
  • Metered Solution Dosing
  • Controlled Contact Time
  • Separate Rinse Circuit
  • Chemical-Resistant Wetted Parts
Запрос котировки Просмотреть продукты

Введение продукции

This decontamination shower combines a covered mixing vessel, dosing pump and circulation manifold for repeatable treatment of the exterior of compatible protective suits. The design separates the treatment circuit from the final water rinse and directs used liquid to a designated drain route. Material selection for seals, pump components and pipework is matched to the selected process chemistry.

Основные характеристики

A covered tank and dosing pump reduce open handling of treatment liquid.

Recirculation maintains nozzle pressure during the chosen contact period.

Separate treatment and rinse branches reduce unintended chemical carryover.

Instrument ports allow solution level, temperature or concentration monitoring.

Surrounding spray zones reach the front, back, hood and boot surfaces.

Обеспокоенность клиентов продуктами

Chemical suit treatment depends on accurate dilution, full exterior wetting and materials compatible with the selected liquid.

Manual mixing gives inconsistent treatment concentration.A metering pump doses solution into a defined water volume in the covered tank.
Suit folds and rear surfaces receive insufficient contact.Multi-side spray zones operate for the selected dwell time with rotation guidance.
A chosen chemical damages ordinary elastomers or pump materials.Wetted components are selected for the actual treatment chemistry.
Used solution cannot enter a standard sanitary drain.A dedicated trapped outlet can connect to the facility’s controlled effluent route.

Типичные приложения

High-containment research exitsHazardous chemical laboratoriesPositive-pressure suit roomsBiological process support areas

Технические параметры

Typical corrosion-resistant construction ranges for a chemical suit shower are provided below.

Основной материалPIR-insulated SUS 316L enclosure with chemical-compatible spray circuit, mix tank and dosing pump
Толщина панели75-100 mm chemical-resistant insulated panels
эффективная ширина1000-1400 mm clear treatment-zone width
Максимальная длинаUp to 2500 mm complete chamber length
Толщина линий стали1.2-2.0 mm SUS 316L wetted facing
Плотность ядра40-45 kg/m³ closed-cell PIR insulation
Теплопроводимость0.021-0.026 W/(m·K) for the insulated shell
Поверхностная отделкаPassivated SUS 316L with smooth welded corners and chemistry-compatible seals
Объединенный типContinuously sealed enclosure joints with sanitary piping and isolated treatment and rinse manifolds
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Single-pass or recirculating processSolution concentration monitoringHeated treatment tankEffluent collection skid

Planning a Chemical Protective-Suit Decontamination Shower specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat