Painel de parede de ar de retorno para sala limpa
- Concealed Return-Air Path
- Low-Level Intake Grille
- Flush Wall Integration
- Accessible Pre-Filter Option
Introdução do produto
The Cleanroom Return-Air Riser Wall Panel replaces a separate floor-to-ceiling return column with a prefabricated hollow module. Room air enters through a flush grille near floor level, travels upward inside a protected channel and connects to the recirculation plenum or return duct above the ceiling. Gypsum lining and aluminum honeycomb reinforcement stiffen the wide cavity without blocking airflow. A lift-out or hinged intake section gives maintenance access to the optional coarse pre-filter while the remaining wall face stays aligned with adjacent cleanroom panels.
Características-chave
Low-wall collection removes air near the zone where heavier particles tend to settle.
A flush stainless steel or coated grille preserves a smooth partition profile.
The optional washable pre-filter can be reached from the clean side through a dedicated cover.
Factory-formed top and bottom transitions reduce leakage around the riser connection.
Preocupações do produto do cliente
Return-wall concerns center on lost floor space, inaccessible filters, noisy air velocity and leakage at duct transitions.
Aplicações típicas
Parâmetros técnicos
This specification follows the common 100 mm integrated return-air wall module used in modular cleanroom systems.
| Material principal | 12 mm gypsum liner with aluminum honeycomb reinforcement around a hollow air channel |
|---|---|
| Painel de espessura | 100 mm |
| Largura efetiva | 980 ou 1180 mm |
| Comprimento máximo | 6000 mm |
| Aço enfrentando espessura | 0.50 mm |
| Densidade Core | 750–900 kg/m³ gypsum liner and approximately 27 kg/m³ aluminum honeycomb |
| Condutividade térmica | 0.17–0.25 W/(m·K) for the lined air-channel assembly |
| Superfície acabado | PE-, HDP- or PVDF-coated steel; stainless steel intake face available |
| Tipo conjunto | Sealed hollow tongue-and-groove riser with flush removable return grille |
| Customização | Riser width, grille size and filter access can be adapted to the intended airflow arrangement |
Opções disponíveis
Planning a Cleanroom Return-Air Riser Wall Panel specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã