Cleanroom Return-Air Riser Wall Panel
- Concealed Return-Air Path
- Low-Level Intake Grille
- Flush Wall Integration
- Accessible Pre-Filter Option
Perkenalan produk
The Cleanroom Return-Air Riser Wall Panel replaces a separate floor-to-ceiling return column with a prefabricated hollow module. Room air enters through a flush grille near floor level, travels upward inside a protected channel and connects to the recirculation plenum or return duct above the ceiling. Gypsum lining and aluminum honeycomb reinforcement stiffen the wide cavity without blocking airflow. A lift-out or hinged intake section gives maintenance access to the optional coarse pre-filter while the remaining wall face stays aligned with adjacent cleanroom panels.
Fitur utama:
Low-wall collection removes air near the zone where heavier particles tend to settle.
A flush stainless steel or coated grille preserves a smooth partition profile.
The optional washable pre-filter can be reached from the clean side through a dedicated cover.
Factory-formed top and bottom transitions reduce leakage around the riser connection.
Kekhawatiran produk pelanggan
Return-wall concerns center on lost floor space, inaccessible filters, noisy air velocity and leakage at duct transitions.
Aplikasi yang Tipis
Parameter teknis
This specification follows the common 100 mm integrated return-air wall module used in modular cleanroom systems.
| Bahan inti | 12 mm gypsum liner with aluminum honeycomb reinforcement around a hollow air channel |
|---|---|
| Ketebalan Panel (Panel Thickness) | 100 mm |
| Efektif lebar | 980 atau 1180 mm |
| Panjang maksimum | 6000 mm ZXQ000003 |
| Baja menghadap ketebalan | 0.50 mm |
| Kepadatan inti (core density) | 750–900 kg/m³ gypsum liner and approximately 27 kg/m³ aluminum honeycomb |
| Konduktivitas Termal (Thermal Conductivity) | 0.17–0.25 W/(m·K) for the lined air-channel assembly |
| Permukaan selesai | PE-, HDP- or PVDF-coated steel; stainless steel intake face available |
| Jenis Bersama | Sealed hollow tongue-and-groove riser with flush removable return grille |
| Customization (Kustomisasi) | Riser width, grille size and filter access can be adapted to the intended airflow arrangement |
Pilihan yang tersedia
Planning a Cleanroom Return-Air Riser Wall Panel specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.