Sala limpia retorno de aire Riser Panel de pared por
- Concealed Return-Air Path
- Low-Level Intake Grille
- Flush Wall Integration
- Accessible Pre-Filter Option
Introducción del producto
The Cleanroom Return-Air Riser Wall Panel replaces a separate floor-to-ceiling return column with a prefabricated hollow module. Room air enters through a flush grille near floor level, travels upward inside a protected channel and connects to the recirculation plenum or return duct above the ceiling. Gypsum lining and aluminum honeycomb reinforcement stiffen the wide cavity without blocking airflow. A lift-out or hinged intake section gives maintenance access to the optional coarse pre-filter while the remaining wall face stays aligned with adjacent cleanroom panels.
Características clave
Low-wall collection removes air near the zone where heavier particles tend to settle.
A flush stainless steel or coated grille preserves a smooth partition profile.
The optional washable pre-filter can be reached from the clean side through a dedicated cover.
Factory-formed top and bottom transitions reduce leakage around the riser connection.
Preocupaciones del producto del cliente
Return-wall concerns center on lost floor space, inaccessible filters, noisy air velocity and leakage at duct transitions.
Aplicaciones típicas
Parámetros técnicos
This specification follows the common 100 mm integrated return-air wall module used in modular cleanroom systems.
| Materiales Core | 12 mm gypsum liner with aluminum honeycomb reinforcement around a hollow air channel |
|---|---|
| Panel de espesor | 100 mm |
| Ancho efectivo | 980 o 1180 mm |
| Longitud máxima | 6000 mm |
| Acero frente a espesor | 0.50 mm |
| Densidad Core | 750–900 kg/m³ gypsum liner and approximately 27 kg/m³ aluminum honeycomb |
| Conductividad térmica | 0.17–0.25 W/(m·K) for the lined air-channel assembly |
| Superficie acabada | PE-, HDP- or PVDF-coated steel; stainless steel intake face available |
| Tipo conjunto | Sealed hollow tongue-and-groove riser with flush removable return grille |
| Customization | Riser width, grille size and filter access can be adapted to the intended airflow arrangement |
Opciones disponibles
Planning a Cleanroom Return-Air Riser Wall Panel specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita