Panel Dinding Riser Kembali Ruang Bersih
- Concealed Return-Air Path
- Low-Level Intake Grille
- Flush Wall Integration
- Accessible Pre-Filter Option
Pengenalan Produk
The Cleanroom Return-Air Riser Wall Panel replaces a separate floor-to-ceiling return column with a prefabricated hollow module. Room air enters through a flush grille near floor level, travels upward inside a protected channel and connects to the recirculation plenum or return duct above the ceiling. Gypsum lining and aluminum honeycomb reinforcement stiffen the wide cavity without blocking airflow. A lift-out or hinged intake section gives maintenance access to the optional coarse pre-filter while the remaining wall face stays aligned with adjacent cleanroom panels.
Ciri-ciri Utama
Low-wall collection removes air near the zone where heavier particles tend to settle.
A flush stainless steel or coated grille preserves a smooth partition profile.
The optional washable pre-filter can be reached from the clean side through a dedicated cover.
Factory-formed top and bottom transitions reduce leakage around the riser connection.
Kebimbangan Produk Pelanggan
Return-wall concerns center on lost floor space, inaccessible filters, noisy air velocity and leakage at duct transitions.
Permohonan yang biasa
Parameter teknikal
This specification follows the common 100 mm integrated return-air wall module used in modular cleanroom systems.
| Bahan Teras | 12 mm gypsum liner with aluminum honeycomb reinforcement around a hollow air channel |
|---|---|
| Ketebalan Panel | 100 mm |
| Lebar berkesan | 980 or 1180 mm |
| Panjang maksimum | 6000 mm |
| Keluli Menghadapi Ketebalan | 0.50 mm |
| Ketumpatan teras | 750–900 kg/m³ gypsum liner and approximately 27 kg/m³ aluminum honeycomb |
| Kekonduksian Terma | 0.17–0.25 W/(m·K) for the lined air-channel assembly |
| Kemasan permukaan | PE-, HDP- or PVDF-coated steel; stainless steel intake face available |
| Jenis Bersatu | Sealed hollow tongue-and-groove riser with flush removable return grille |
| Penyesuaian | Riser width, grille size and filter access can be adapted to the intended airflow arrangement |
Pilihan yang boleh didapati
Planning a Cleanroom Return-Air Riser Wall Panel specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)