Temiz Oda Return-Air Riser Duvar Panelleri
- Concealed Return-Air Path
- Low-Level Intake Grille
- Flush Wall Integration
- Accessible Pre-Filter Option
Ürün tanıtımı
The Cleanroom Return-Air Riser Wall Panel replaces a separate floor-to-ceiling return column with a prefabricated hollow module. Room air enters through a flush grille near floor level, travels upward inside a protected channel and connects to the recirculation plenum or return duct above the ceiling. Gypsum lining and aluminum honeycomb reinforcement stiffen the wide cavity without blocking airflow. A lift-out or hinged intake section gives maintenance access to the optional coarse pre-filter while the remaining wall face stays aligned with adjacent cleanroom panels.
Ana Özellikler
Low-wall collection removes air near the zone where heavier particles tend to settle.
A flush stainless steel or coated grille preserves a smooth partition profile.
The optional washable pre-filter can be reached from the clean side through a dedicated cover.
Factory-formed top and bottom transitions reduce leakage around the riser connection.
Müşteri Ürün Sorunları
Return-wall concerns center on lost floor space, inaccessible filters, noisy air velocity and leakage at duct transitions.
Tipik uygulamalar
Teknik parametreler
This specification follows the common 100 mm integrated return-air wall module used in modular cleanroom systems.
| Temel malzemeler | 12 mm gypsum liner with aluminum honeycomb reinforcement around a hollow air channel |
|---|---|
| Panel kalınlığı | 100 mm |
| Effective Width (Etkili Genişlik) | 980 or 1180 mm |
| Maksimum uzunluk | 6000 mm |
| Çelik yüz yüze kalınlığı | 0.50 mm |
| Core Density (Çekirdek Yoğunluğu) | 750–900 kg/m³ gypsum liner and approximately 27 kg/m³ aluminum honeycomb |
| Termal İletkenlik | 0.17–0.25 W/(m·K) for the lined air-channel assembly |
| Yüzey bitirme | PE-, HDP- or PVDF-coated steel; stainless steel intake face available |
| Ortak tip | Sealed hollow tongue-and-groove riser with flush removable return grille |
| Customization (Özelleşme) | Riser width, grille size and filter access can be adapted to the intended airflow arrangement |
Mevcut Seçenekler
Planning a Cleanroom Return-Air Riser Wall Panel specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.