Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Fluxo laminar e equipamentos de contenção / Class II Type A2 Biological Safety Cabinet
Fluxo laminar e equipamentos de contenção

Gabinete de Segurança Biológica Classe II Tipo A2

A recirculating Class II cabinet that combines inward face airflow, HEPA-filtered vertical downflow and filtered exhaust for three-way protection.
  • Personnel Product and Environmental Protection
  • HEPA-Filtered Downflow
  • Negative-Pressure Contaminated Plenums
  • Recirculating A2 Airflow
Solicite um orçamento. Browse produtos

Introdução do produto

The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.

Características-chave

The front inflow grille captures room air before it crosses the work surface.

Vertical filtered downflow limits cross-contamination across the product zone.

Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.

A motorized or counterbalanced sash maintains the selected operating height.

Independent inflow and downflow sensing supports real-time airflow monitoring.

Preocupações do produto do cliente

A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.

Hands crossing the front grille disrupt containment.A properly sized grille and stable inflow maintain capture around normal arm movement.
Items block downflow and create cross-contamination zones.A wide supply diffuser and organized work layout preserve first-air paths.
Filter loading shifts the inflow/downflow balance.Separate airflow sensors and automatic blower control maintain the selected operating range.
The cabinet is used with unsuitable volatile chemicals.Application guidance distinguishes A2 biological particulate work from total-exhaust chemical handling.

Aplicações típicas

Cell cultureClinical microbiologyNon-volatile biological sample preparationSterile biological product handling

Parâmetros técnicos

Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.

Material principalSUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure
Painel de espessura30-60 mm double-wall cabinet and plenum sections
Largura efetiva900 - 1800 mm largura de trabalho clara
Comprimento máximoUp to 2400 mm overall cabinet height
Aço enfrentando espessura1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel
Densidade Core80 - 120 kg / m3 de enchimento acústico de lã mineral
Condutividade térmica0,035 - 0,045 W / (m · K) para o enchimento acústico
Superfície acabadoFine-brushed SUS304 work zone with white epoxy-polyester outer coating
Tipo conjuntoWelded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

900-1800 mm work widthsRoom exhaust or canopy connectionMotorized sashSingle-piece or segmented work tray

Planning a Class II Type A2 Biological Safety Cabinet specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe