Klasse II Typ A2 Biologische Sicherheit Schrank
- Personnel Product and Environmental Protection
- HEPA-Filtered Downflow
- Negative-Pressure Contaminated Plenums
- Recirculating A2 Airflow
Produkteinführung
The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.
Key Features
Vertical filtered downflow limits cross-contamination across the product zone.
Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.
A motorized or counterbalanced sash maintains the selected operating height.
Independent inflow and downflow sensing supports real-time airflow monitoring.
Kunden Produktbedenken
A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.
Typische Anwendungen
Technische Parameter
Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.
| Core Material | SUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure |
|---|---|
| Panel Dicke | 30-60 mm double-wall cabinet and plenum sections |
| Effektive Breite | 900 - 1800 mm klare Arbeitsbreite |
| Maximale Länge | Up to 2400 mm overall cabinet height |
| Stahl facing Dicke | 1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel |
| Kerndichte | 80 - 120 kg / m3 Mineralwolle Akustikfüllung |
| Thermische Leitfähigkeit | 0,035 - 0,045 W / (m · K) für die Akustikfüllung |
| Oberfläche Finish | Fine-brushed SUS304 work zone with white epoxy-polyester outer coating |
| Gemeinsamer Typ | Welded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Class II Type A2 Biological Safety Cabinet specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.