Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement d'écoulement et de confinement laminaires / Class II Type A2 Biological Safety Cabinet
Équipement d'écoulement et de confinement laminaires

Cabinet de sécurité biologique de type A2 de classe II

A recirculating Class II cabinet that combines inward face airflow, HEPA-filtered vertical downflow and filtered exhaust for three-way protection.
  • Personnel Product and Environmental Protection
  • HEPA-Filtered Downflow
  • Negative-Pressure Contaminated Plenums
  • Recirculating A2 Airflow
Demander un devis. Browse les produits

Introduction de produit

The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.

Key Features

The front inflow grille captures room air before it crosses the work surface.

Vertical filtered downflow limits cross-contamination across the product zone.

Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.

A motorized or counterbalanced sash maintains the selected operating height.

Independent inflow and downflow sensing supports real-time airflow monitoring.

Préoccupations du client produit

A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.

Hands crossing the front grille disrupt containment.A properly sized grille and stable inflow maintain capture around normal arm movement.
Items block downflow and create cross-contamination zones.A wide supply diffuser and organized work layout preserve first-air paths.
Filter loading shifts the inflow/downflow balance.Separate airflow sensors and automatic blower control maintain the selected operating range.
The cabinet is used with unsuitable volatile chemicals.Application guidance distinguishes A2 biological particulate work from total-exhaust chemical handling.

Les applications typiques

Cell cultureClinical microbiologyNon-volatile biological sample preparationSterile biological product handling

Paramètres techniques

Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.

Matériaux de baseSUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure
Panneau épaisseur30-60 mm double-wall cabinet and plenum sections
Largeur effective900 - 1800 mm Largeur de travail claire
Longueur maximaleUp to 2400 mm overall cabinet height
Acier face épaisseur1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel
Densité Core80 - 120 kg / m3 remplissage acoustique en laine minérale par
Conductivité thermique0,035 - 0,045 W / (m · K) pour le remplissage acoustique
surface finieFine-brushed SUS304 work zone with white epoxy-polyester outer coating
Type jointWelded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

900-1800 mm work widthsRoom exhaust or canopy connectionMotorized sashSingle-piece or segmented work tray

Planning a Class II Type A2 Biological Safety Cabinet specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact