ホーム / 製品 / 層流 · 封じ込め装置 / Class II Type A2 Biological Safety Cabinet
層流 · 封じ込め装置

Class II タイプ A2 生物安全キャビネット

A recirculating Class II cabinet that combines inward face airflow, HEPA-filtered vertical downflow and filtered exhaust for three-way protection.
  • Personnel Product and Environmental Protection
  • HEPA-Filtered Downflow
  • Negative-Pressure Contaminated Plenums
  • Recirculating A2 Airflow
見積もりリクエスト 製品案内

商品紹介

The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.

主要な特徴

The front inflow grille captures room air before it crosses the work surface.

Vertical filtered downflow limits cross-contamination across the product zone.

Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.

A motorized or counterbalanced sash maintains the selected operating height.

Independent inflow and downflow sensing supports real-time airflow monitoring.

お客様の製品に関する懸念事項

A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.

Hands crossing the front grille disrupt containment.A properly sized grille and stable inflow maintain capture around normal arm movement.
Items block downflow and create cross-contamination zones.A wide supply diffuser and organized work layout preserve first-air paths.
Filter loading shifts the inflow/downflow balance.Separate airflow sensors and automatic blower control maintain the selected operating range.
The cabinet is used with unsuitable volatile chemicals.Application guidance distinguishes A2 biological particulate work from total-exhaust chemical handling.

典型的な用途

Cell cultureClinical microbiologyNon-volatile biological sample preparationSterile biological product handling

技術的なパラメータ

Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.

コア材料SUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure
パネルの厚さ30-60 mm double-wall cabinet and plenum sections
有効幅900 — 1800 mm 明確な作業幅
最大長さUp to 2400 mm overall cabinet height
鋼鉄の厚さを直面する1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel
コア密度80 — 120 kg / m3 ミネラルウール音響インフィル
熱伝導率0.035 — 0.045 W / (m · K) 音響インフィルのための
表面仕上げFine-brushed SUS304 work zone with white epoxy-polyester outer coating
ジョイントタイプWelded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

900-1800 mm work widthsRoom exhaust or canopy connectionモーター付きサッシュSingle-piece or segmented work tray

Planning a Class II Type A2 Biological Safety Cabinet specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。