A recirculating Class II cabinet that combines inward face airflow, HEPA-filtered vertical downflow and filtered exhaust for three-way protection.
  • Personnel Product and Environmental Protection
  • HEPA-Filtered Downflow
  • Negative-Pressure Contaminated Plenums
  • Recirculating A2 Airflow
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.

Ciri-ciri Utama

The front inflow grille captures room air before it crosses the work surface.

Vertical filtered downflow limits cross-contamination across the product zone.

Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.

A motorized or counterbalanced sash maintains the selected operating height.

Independent inflow and downflow sensing supports real-time airflow monitoring.

Kebimbangan Produk Pelanggan

A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.

Hands crossing the front grille disrupt containment.A properly sized grille and stable inflow maintain capture around normal arm movement.
Items block downflow and create cross-contamination zones.A wide supply diffuser and organized work layout preserve first-air paths.
Filter loading shifts the inflow/downflow balance.Separate airflow sensors and automatic blower control maintain the selected operating range.
The cabinet is used with unsuitable volatile chemicals.Application guidance distinguishes A2 biological particulate work from total-exhaust chemical handling.

Permohonan yang biasa

Cell cultureClinical microbiologyNon-volatile biological sample preparationSterile biological product handling

Parameter teknikal

Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.

Bahan TerasSUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure
Ketebalan Panel30-60 mm double-wall cabinet and plenum sections
Lebar berkesan900-1800 mm lebar kerja yang jelas
Panjang maksimumUp to 2400 mm overall cabinet height
Keluli Menghadapi Ketebalan1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel
Ketumpatan teras80-120 kg / m3 mineral-wool infill akustik
Kekonduksian Terma0.035-0.045 W / (m · K) untuk pengisian akustik
Kemasan permukaanFine-brushed SUS304 work zone with white epoxy-polyester outer coating
Jenis BersatuWelded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

900-1800 mm work widthsRoom exhaust or canopy connectionMotorized sashSingle-piece or segmented work tray

Planning a Class II Type A2 Biological Safety Cabinet specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.