Kelas II Jenis A2 Kabinet Keselamatan Biologi
- Personnel Product and Environmental Protection
- HEPA-Filtered Downflow
- Negative-Pressure Contaminated Plenums
- Recirculating A2 Airflow
Pengenalan Produk
The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.
Ciri-ciri Utama
Vertical filtered downflow limits cross-contamination across the product zone.
Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.
A motorized or counterbalanced sash maintains the selected operating height.
Independent inflow and downflow sensing supports real-time airflow monitoring.
Kebimbangan Produk Pelanggan
A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.
Permohonan yang biasa
Parameter teknikal
Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.
| Bahan Teras | SUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure |
|---|---|
| Ketebalan Panel | 30-60 mm double-wall cabinet and plenum sections |
| Lebar berkesan | 900-1800 mm lebar kerja yang jelas |
| Panjang maksimum | Up to 2400 mm overall cabinet height |
| Keluli Menghadapi Ketebalan | 1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel |
| Ketumpatan teras | 80-120 kg / m3 mineral-wool infill akustik |
| Kekonduksian Terma | 0.035-0.045 W / (m · K) untuk pengisian akustik |
| Kemasan permukaan | Fine-brushed SUS304 work zone with white epoxy-polyester outer coating |
| Jenis Bersatu | Welded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Class II Type A2 Biological Safety Cabinet specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)