Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Aliran Laminar dan Peralatan Penahanan / Class II Type A2 Biological Safety Cabinet
Aliran Laminar dan Peralatan Penahanan

Kabinet Keamanan Biologi Kelas II Tipe A2

A recirculating Class II cabinet that combines inward face airflow, HEPA-filtered vertical downflow and filtered exhaust for three-way protection.
  • Personnel Product and Environmental Protection
  • HEPA-Filtered Downflow
  • Negative-Pressure Contaminated Plenums
  • Recirculating A2 Airflow
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.

Fitur utama:

The front inflow grille captures room air before it crosses the work surface.

Vertical filtered downflow limits cross-contamination across the product zone.

Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.

A motorized or counterbalanced sash maintains the selected operating height.

Independent inflow and downflow sensing supports real-time airflow monitoring.

Kekhawatiran produk pelanggan

A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.

Hands crossing the front grille disrupt containment.A properly sized grille and stable inflow maintain capture around normal arm movement.
Items block downflow and create cross-contamination zones.A wide supply diffuser and organized work layout preserve first-air paths.
Filter loading shifts the inflow/downflow balance.Separate airflow sensors and automatic blower control maintain the selected operating range.
The cabinet is used with unsuitable volatile chemicals.Application guidance distinguishes A2 biological particulate work from total-exhaust chemical handling.

Aplikasi yang Tipis

Cell cultureClinical microbiologyNon-volatile biological sample preparationSterile biological product handling

Parameter teknis

Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.

Bahan intiSUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure
Ketebalan Panel (Panel Thickness)30-60 mm double-wall cabinet and plenum sections
Efektif lebar900 - 1800 mm lebar kerja yang jelas
Panjang maksimumUp to 2400 mm overall cabinet height
Baja menghadap ketebalan1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel
Kepadatan inti (core density)80 - 120 kg / m3 mineral-wol akustik infill
Konduktivitas Termal (Thermal Conductivity)0,035 - 0,045 W / (m · K) untuk infill akustik
Permukaan selesaiFine-brushed SUS304 work zone with white epoxy-polyester outer coating
Jenis BersamaWelded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

900-1800 mm work widthsRoom exhaust or canopy connectionMotorized sashSingle-piece or segmented work tray

Planning a Class II Type A2 Biological Safety Cabinet specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami