Kabinet Keamanan Biologi Kelas II Tipe A2
- Personnel Product and Environmental Protection
- HEPA-Filtered Downflow
- Negative-Pressure Contaminated Plenums
- Recirculating A2 Airflow
Perkenalan produk
The Type A2 cabinet draws room air inward at the front grille while HEPA-filtered downflow protects the work zone. A portion of the filtered air is recirculated and the balance is exhausted through a HEPA stage, either into the room or through an appropriate canopy connection. Contaminated plenums are maintained under negative pressure or surrounded by negative-pressure sections. The cabinet is selected and installed for biological particulate work; volatile chemical use requires a separately evaluated exhaust strategy.
Fitur utama:
Vertical filtered downflow limits cross-contamination across the product zone.
Negative-pressure plenum design provides a fail-safe boundary around contaminated air paths.
A motorized or counterbalanced sash maintains the selected operating height.
Independent inflow and downflow sensing supports real-time airflow monitoring.
Kekhawatiran produk pelanggan
A Type A2 cabinet must balance operator capture and clean product downflow while keeping recirculated air paths safely enclosed.
Aplikasi yang Tipis
Parameter teknis
Typical configurable construction ranges for a Class II Type A2 biological safety cabinet are listed below.
| Bahan inti | SUS304 single-piece work-zone liner with powder-coated steel outer shell and mineral-wool acoustic fan enclosure |
|---|---|
| Ketebalan Panel (Panel Thickness) | 30-60 mm double-wall cabinet and plenum sections |
| Efektif lebar | 900 - 1800 mm lebar kerja yang jelas |
| Panjang maksimum | Up to 2400 mm overall cabinet height |
| Baja menghadap ketebalan | 1.0-1.5 mm SUS304 inner liner; 0.9-1.2 mm outer steel |
| Kepadatan inti (core density) | 80 - 120 kg / m3 mineral-wol akustik infill |
| Konduktivitas Termal (Thermal Conductivity) | 0,035 - 0,045 W / (m · K) untuk infill akustik |
| Permukaan selesai | Fine-brushed SUS304 work zone with white epoxy-polyester outer coating |
| Jenis Bersama | Welded inner liner with negative-pressure plenum joints and gasketed supply and exhaust HEPA frames |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Class II Type A2 Biological Safety Cabinet specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Jerman
Bahasa Arab
Bahasa Perancis: Bahasa Perancis
Bahasa IndonesiaSaat ini
Bahasa Jepang
Bahasa Korea
Bahasa Melayu
Bahasa Portugis
Bahasa Rusia
Bahasa Spanyol
Bahasa Thailand
Bahasa Turki