كاشف التسرب الكيميائي

A point or cable-based detector that identifies liquid chemical leaks beneath process tools, tanks and distribution piping.
  • Point or Cable Sensing
  • Early Localized Leak Warning
  • Replaceable Sensor Elements
  • Remote Alarm Integration
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The chemical leak detector monitors a selected point probe or sensing cable for contact with compatible liquids. A controller evaluates the sensor, identifies alarm and fault conditions, and sends local and remote outputs to operators, exhaust systems or chemical shutdown controls. Probe chemistry and cable construction are selected for the expected acid, base, solvent or water-based liquid.

الخصائص الرئيسية

Distributed sensing cable covers long pipe and equipment perimeters.

Point probes target sumps, drip trays and low collection points.

Separate alarm and cable-fault supervision improve diagnostics.

Relay, analog or network outputs integrate with facility controls.

مخاوف المنتج للعملاء

A small hidden chemical release can travel beneath equipment before operators see it, causing corrosion and extended shutdown.

Visual inspections miss leaks under enclosed tools.Sensing cable or point probes continuously monitor concealed collection paths.
One sensing material is not compatible with every chemical.Sensor chemistry is selected for the actual liquid inventory.
A broken cable can appear identical to a dry condition.Continuity supervision reports open-circuit and controller faults separately.
Operators need to isolate the source quickly.Zoned controllers or distance-locating cable identify the affected section.

تطبيقات نموذجية

Wet process toolsChemical distribution roomsLaboratory benchesTank and pump skids

المعلمات الفنية

Typical controller construction is listed below; sensor material, cable length and zoning follow the chemical distribution layout.

المواد الأساسيةPowder-coated steel controller with chemical-compatible point probe or sensing cable
سمك اللوحة1.0-1.5 mm controller enclosure
العرض الفعال150-350 mm controller width
الحد الأقصى الطولUp to 500 mm enclosure height
الصلب يواجه سمك1.0-1.5 mm steel enclosure panels
الكثافة الأساسية7850 kg/m³ for steel enclosure parts
الموصلية الحرارية45-60 W/(m·K) for steel enclosure components
إنهاء السطحSmooth light-gray coating with high-visibility status indicators
نوع المشتركGasketed controller with supervised plug terminals and detachable sensor connectors
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Point probesSensing cableMulti-zone controllerRemote shutdown relays