Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Peralatan Saliran Bilik Bersih, Kebersihan dan Keselamatan

Pengesan Kebocoran Kimia

A point or cable-based detector that identifies liquid chemical leaks beneath process tools, tanks and distribution piping.
  • Point or Cable Sensing
  • Early Localized Leak Warning
  • Replaceable Sensor Elements
  • Remote Alarm Integration
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The chemical leak detector monitors a selected point probe or sensing cable for contact with compatible liquids. A controller evaluates the sensor, identifies alarm and fault conditions, and sends local and remote outputs to operators, exhaust systems or chemical shutdown controls. Probe chemistry and cable construction are selected for the expected acid, base, solvent or water-based liquid.

Ciri-ciri Utama

Distributed sensing cable covers long pipe and equipment perimeters.

Point probes target sumps, drip trays and low collection points.

Separate alarm and cable-fault supervision improve diagnostics.

Relay, analog or network outputs integrate with facility controls.

Kebimbangan Produk Pelanggan

A small hidden chemical release can travel beneath equipment before operators see it, causing corrosion and extended shutdown.

Visual inspections miss leaks under enclosed tools.Sensing cable or point probes continuously monitor concealed collection paths.
One sensing material is not compatible with every chemical.Sensor chemistry is selected for the actual liquid inventory.
A broken cable can appear identical to a dry condition.Continuity supervision reports open-circuit and controller faults separately.
Operators need to isolate the source quickly.Zoned controllers or distance-locating cable identify the affected section.

Permohonan yang biasa

Wet process toolsChemical distribution roomsLaboratory benchesTank and pump skids

Parameter teknikal

Typical controller construction is listed below; sensor material, cable length and zoning follow the chemical distribution layout.

Bahan TerasPowder-coated steel controller with chemical-compatible point probe or sensing cable
Ketebalan Panel1.0-1.5 mm controller enclosure
Lebar berkesan150-350 mm controller width
Panjang maksimumUp to 500 mm enclosure height
Keluli Menghadapi Ketebalan1.0-1.5 mm steel enclosure panels
Ketumpatan teras7850 kg/m³ for steel enclosure parts
Kekonduksian Terma45-60 W/(m·K) for steel enclosure components
Kemasan permukaanSmooth light-gray coating with high-visibility status indicators
Jenis BersatuGasketed controller with supervised plug terminals and detachable sensor connectors
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Point probesSensing cableMulti-zone controllerRemote shutdown relays

Planning a Chemical Leak Detector specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami