A point or cable-based detector that identifies liquid chemical leaks beneath process tools, tanks and distribution piping.
  • Point or Cable Sensing
  • Early Localized Leak Warning
  • Replaceable Sensor Elements
  • Remote Alarm Integration
Solicite un presupuesto. Browse productos

Introducción del producto

The chemical leak detector monitors a selected point probe or sensing cable for contact with compatible liquids. A controller evaluates the sensor, identifies alarm and fault conditions, and sends local and remote outputs to operators, exhaust systems or chemical shutdown controls. Probe chemistry and cable construction are selected for the expected acid, base, solvent or water-based liquid.

Características clave

Distributed sensing cable covers long pipe and equipment perimeters.

Point probes target sumps, drip trays and low collection points.

Separate alarm and cable-fault supervision improve diagnostics.

Relay, analog or network outputs integrate with facility controls.

Preocupaciones del producto del cliente

A small hidden chemical release can travel beneath equipment before operators see it, causing corrosion and extended shutdown.

Visual inspections miss leaks under enclosed tools.Sensing cable or point probes continuously monitor concealed collection paths.
One sensing material is not compatible with every chemical.Sensor chemistry is selected for the actual liquid inventory.
A broken cable can appear identical to a dry condition.Continuity supervision reports open-circuit and controller faults separately.
Operators need to isolate the source quickly.Zoned controllers or distance-locating cable identify the affected section.

Aplicaciones típicas

Wet process toolsChemical distribution roomsLaboratory benchesTank and pump skids

Parámetros técnicos

Typical controller construction is listed below; sensor material, cable length and zoning follow the chemical distribution layout.

Materiales CorePowder-coated steel controller with chemical-compatible point probe or sensing cable
Panel de espesor1.0-1.5 mm controller enclosure
Ancho efectivo150-350 mm controller width
Longitud máximaUp to 500 mm enclosure height
Acero frente a espesor1.0-1.5 mm steel enclosure panels
Densidad Core7850 kg/m³ for steel enclosure parts
Conductividad térmica45-60 W/(m·K) for steel enclosure components
Superficie acabadaSmooth light-gray coating with high-visibility status indicators
Tipo conjuntoGasketed controller with supervised plug terminals and detachable sensor connectors
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Point probesSensing cableMulti-zone controllerRemote shutdown relays

Planning a Chemical Leak Detector specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto