Suministro de energía de emergencia para sala limpia

A central battery and changeover cabinet that supplies selected cleanroom emergency circuits when the normal source is unavailable.
  • Central Battery Bank
  • Automatic Source Changeover
  • Dedicated Emergency Feeders
  • Monitored Charger and Alarms
Solicite un presupuesto. Browse productos

Introducción del producto

This emergency supply combines a charger, battery bank, inverter or DC distribution, automatic transfer logic and protected outgoing circuits in one monitored system. Unlike a general UPS serving connected equipment, it is arranged around defined emergency loads such as egress lighting, intercom, access release and control circuits. A front mimic display shows source, battery, output and fault conditions.

Características clave

Dedicated outgoing feeders separate emergency loads from normal branch circuits.

Automatic transfer logic energizes the backup path after loss of the monitored source.

The charger maintains the battery and reports low-voltage or battery fault conditions.

A mimic panel displays normal source, standby source and feeder status clearly.

An external maintenance bypass can preserve supply during cabinet service.

Preocupaciones del producto del cliente

Emergency circuits must start reliably, remain clearly segregated and reveal battery or charger faults before a real supply failure.

Emergency and normal loads are mixed in one unmarked panel.Dedicated labeled feeders and separated terminals preserve circuit identity.
A failed charger remains unnoticed until the battery is needed.Continuous battery and charger supervision activates visible and remote alarms.
Transfer delay disrupts sensitive control circuits.The selected inverter or DC architecture matches the continuity requirement of each load.
Servicing the battery cabinet removes all emergency power.An optional maintenance bypass or alternate input supports planned work.

Aplicaciones típicas

Cleanroom emergency lightingDoor-release and intercom backupCritical alarm circuitsSelected ventilation controls

Parámetros técnicos

Typical configurable construction ranges for a cleanroom emergency power supply are listed below.

Materiales CoreSteel or stainless cabinet with charger, batteries, inverter or DC bus, automatic changeover and protected feeders
Panel de espesor400-900 mm cabinet depth
Ancho efectivo600-1600 mm assembled cabinet width
Longitud máximaUp to 2200 mm floor-standing height
Acero frente a espesor1.5-2.0 mm cabinet body and doors
Densidad CoreApproximately 7850-8000 kg/m³ for steel or stainless cabinet material
Conductividad térmica14-60 W/(m·K) depending on stainless or carbon-steel enclosure
Superficie acabadaLight-grey, white or brushed stainless enclosure with colored mimic and alarm indicators
Tipo conjuntoGasketed modular cabinet with separated battery/power compartments and gland-plate cable entries
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

AC inverter or DC outputLithium-ion or VRLA battery bankIntegrated automatic transfer switchRemote alarm communication