상품 소개
This emergency supply combines a charger, battery bank, inverter or DC distribution, automatic transfer logic and protected outgoing circuits in one monitored system. Unlike a general UPS serving connected equipment, it is arranged around defined emergency loads such as egress lighting, intercom, access release and control circuits. A front mimic display shows source, battery, output and fault conditions.
주요 기능
Automatic transfer logic energizes the backup path after loss of the monitored source.
The charger maintains the battery and reports low-voltage or battery fault conditions.
A mimic panel displays normal source, standby source and feeder status clearly.
An external maintenance bypass can preserve supply during cabinet service.
고객 제품 관심사
Emergency circuits must start reliably, remain clearly segregated and reveal battery or charger faults before a real supply failure.
Emergency and normal loads are mixed in one unmarked panel.Dedicated labeled feeders and separated terminals preserve circuit identity.
A failed charger remains unnoticed until the battery is needed.Continuous battery and charger supervision activates visible and remote alarms.
Transfer delay disrupts sensitive control circuits.The selected inverter or DC architecture matches the continuity requirement of each load.
Servicing the battery cabinet removes all emergency power.An optional maintenance bypass or alternate input supports planned work.
일반적인 응용 프로그램
Cleanroom emergency lightingDoor-release and intercom backupCritical alarm circuitsSelected ventilation controls
기술 매개변수
Typical configurable construction ranges for a cleanroom emergency power supply are listed below.
| 핵심 재료 | Steel or stainless cabinet with charger, batteries, inverter or DC bus, automatic changeover and protected feeders |
|---|---|
| 패널 두께 | 400-900 mm cabinet depth |
| 유효 폭 | 600-1600 mm assembled cabinet width |
| 최대 길이 | Up to 2200 mm floor-standing height |
| 강철 면면 두께 | 1.5-2.0 mm cabinet body and doors |
| 코어 밀도 | Approximately 7850-8000 kg/m³ for steel or stainless cabinet material |
| 열전도도 (Thermal Conductivity) | 14-60 W/(m·K) depending on stainless or carbon-steel enclosure |
| 표면 마무리 | Light-grey, white or brushed stainless enclosure with colored mimic and alarm indicators |
| 접합 유형 | Gasketed modular cabinet with separated battery/power compartments and gland-plate cable entries |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
AC inverter or DC outputLithium-ion or VRLA battery bankIntegrated automatic transfer switchRemote alarm communication
Planning a Cleanroom Emergency Power Supply specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.