商品紹介
This emergency supply combines a charger, battery bank, inverter or DC distribution, automatic transfer logic and protected outgoing circuits in one monitored system. Unlike a general UPS serving connected equipment, it is arranged around defined emergency loads such as egress lighting, intercom, access release and control circuits. A front mimic display shows source, battery, output and fault conditions.
主要な特徴
Automatic transfer logic energizes the backup path after loss of the monitored source.
The charger maintains the battery and reports low-voltage or battery fault conditions.
A mimic panel displays normal source, standby source and feeder status clearly.
An external maintenance bypass can preserve supply during cabinet service.
お客様の製品に関する懸念事項
Emergency circuits must start reliably, remain clearly segregated and reveal battery or charger faults before a real supply failure.
Emergency and normal loads are mixed in one unmarked panel.Dedicated labeled feeders and separated terminals preserve circuit identity.
A failed charger remains unnoticed until the battery is needed.Continuous battery and charger supervision activates visible and remote alarms.
Transfer delay disrupts sensitive control circuits.The selected inverter or DC architecture matches the continuity requirement of each load.
Servicing the battery cabinet removes all emergency power.An optional maintenance bypass or alternate input supports planned work.
典型的な用途
Cleanroom emergency lightingDoor-release and intercom backupCritical alarm circuitsSelected ventilation controls
技術的なパラメータ
Typical configurable construction ranges for a cleanroom emergency power supply are listed below.
| コア材料 | Steel or stainless cabinet with charger, batteries, inverter or DC bus, automatic changeover and protected feeders |
|---|---|
| パネルの厚さ | 400-900 mm cabinet depth |
| 有効幅 | 600-1600 mm assembled cabinet width |
| 最大長さ | Up to 2200 mm floor-standing height |
| 鋼鉄の厚さを直面する | 1.5-2.0 mm cabinet body and doors |
| コア密度 | Approximately 7850-8000 kg/m³ for steel or stainless cabinet material |
| 熱伝導率 | 14-60 W/(m·K) depending on stainless or carbon-steel enclosure |
| 表面仕上げ | Light-grey, white or brushed stainless enclosure with colored mimic and alarm indicators |
| ジョイントタイプ | Gasketed modular cabinet with separated battery/power compartments and gland-plate cable entries |
| カスタマイズ | 意図したアプリケーションと動作環境に基づいて利用できます。 |
利用可能なオプション
AC inverter or DC outputLithium-ion or VRLA battery bankIntegrated automatic transfer switchRemote alarm communication
Planning a Cleanroom Emergency Power Supply specification?
寸法、設置条件、性能目標、必要な表面仕上げをお送りください。