Датчик кислорода

A fixed electrochemical oxygen monitor that warns of oxygen depletion or enrichment near inert-gas and process-gas use areas.
  • Electrochemical O₂ Measurement
  • Local Concentration Display
  • Dual Alarm Relays
  • Replaceable Sensor Cell
Запрос котировки Просмотреть продукты

Введение продукции

The oxygen depletion sensor continuously samples surrounding air through a protected diffusion cap. An electrochemical cell produces a signal proportional to oxygen partial pressure, and internal electronics display the concentration and compare it with independent alarm thresholds. Local sounder and beacon functions can be supplemented by relay, current or digital outputs to a central alarm system. The replaceable cell and accessible calibration interface support planned maintenance without replacing the wall-mounted transmitter body.

Основные характеристики

Diffusion-based electrochemical sensing requires no sample pump for normal room monitoring.

A bright local display shows oxygen concentration before and during an alarm condition.

Separate low and high alarm thresholds address depletion and enrichment risks.

Replaceable sensing cells extend transmitter service life and simplify maintenance planning.

Обеспокоенность клиентов продуктами

Oxygen hazards can develop without odor or visible warning, so room coverage, alarm visibility and sensor maintenance must be deliberate.

Inert-gas leakage displaces oxygen without giving occupants a sensory warning.Continuous oxygen measurement activates visible and audible alarms before entry or exposure continues.
A sensor mounted too high misses heavier or poorly mixed displacement patterns.Risk-based mounting positions place detectors near credible gas accumulation and breathing zones.
An aged electrochemical cell loses response gradually.Planned bump checks, calibration and replaceable cells maintain response confidence.
A local alarm is not seen from outside the room.Relay and network outputs drive corridor beacons, central annunciation and ventilation actions.

Типичные приложения

Nitrogen-supplied cleanroomsCryogenic storage support areasGas cabinet roomsLaboratory inert-gas zones

Технические параметры

Typical construction values for a fixed oxygen depletion sensor are listed below.

Основной материалReplaceable electrochemical oxygen cell in polycarbonate transmitter with stainless protective sensor guard
Толщина панели55-90 mm detector depth
эффективная ширина110-180 mm housing width
Максимальная длинаUp to 240 mm detector height
Толщина линий стали0.5-1.0 mm stainless sensor guard
Плотность ядра1180-1220 kg/m³ for polycarbonate transmitter body
Теплопроводимость0.19-0.22 W/(m·K) for polycarbonate enclosure material
Поверхностная отделкаWhite or safety-yellow housing with black display, green normal light and red alarm beacon
Объединенный типWall-mount base with diffusion sensor cap, cable gland and removable alarm terminals
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Local sounder and beaconLow and high oxygen alarmsAnalog and relay outputsRemote corridor indicator