Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Control de salas limpias y sistemas de monitoreo ambiental

Sensor de oxígeno

A fixed electrochemical oxygen monitor that warns of oxygen depletion or enrichment near inert-gas and process-gas use areas.
  • Electrochemical O₂ Measurement
  • Local Concentration Display
  • Dual Alarm Relays
  • Replaceable Sensor Cell
Solicite un presupuesto. Browse productos

Introducción del producto

The oxygen depletion sensor continuously samples surrounding air through a protected diffusion cap. An electrochemical cell produces a signal proportional to oxygen partial pressure, and internal electronics display the concentration and compare it with independent alarm thresholds. Local sounder and beacon functions can be supplemented by relay, current or digital outputs to a central alarm system. The replaceable cell and accessible calibration interface support planned maintenance without replacing the wall-mounted transmitter body.

Características clave

Diffusion-based electrochemical sensing requires no sample pump for normal room monitoring.

A bright local display shows oxygen concentration before and during an alarm condition.

Separate low and high alarm thresholds address depletion and enrichment risks.

Replaceable sensing cells extend transmitter service life and simplify maintenance planning.

Preocupaciones del producto del cliente

Oxygen hazards can develop without odor or visible warning, so room coverage, alarm visibility and sensor maintenance must be deliberate.

Inert-gas leakage displaces oxygen without giving occupants a sensory warning.Continuous oxygen measurement activates visible and audible alarms before entry or exposure continues.
A sensor mounted too high misses heavier or poorly mixed displacement patterns.Risk-based mounting positions place detectors near credible gas accumulation and breathing zones.
An aged electrochemical cell loses response gradually.Planned bump checks, calibration and replaceable cells maintain response confidence.
A local alarm is not seen from outside the room.Relay and network outputs drive corridor beacons, central annunciation and ventilation actions.

Aplicaciones típicas

Nitrogen-supplied cleanroomsCryogenic storage support areasGas cabinet roomsLaboratory inert-gas zones

Parámetros técnicos

Typical construction values for a fixed oxygen depletion sensor are listed below.

Materiales CoreReplaceable electrochemical oxygen cell in polycarbonate transmitter with stainless protective sensor guard
Panel de espesor55-90 mm detector depth
Ancho efectivo110-180 mm housing width
Longitud máximaUp to 240 mm detector height
Acero frente a espesor0.5-1.0 mm stainless sensor guard
Densidad Core1180-1220 kg/m³ for polycarbonate transmitter body
Conductividad térmica0.19-0.22 W/(m·K) for polycarbonate enclosure material
Superficie acabadaWhite or safety-yellow housing with black display, green normal light and red alarm beacon
Tipo conjuntoWall-mount base with diffusion sensor cap, cable gland and removable alarm terminals
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Local sounder and beaconLow and high oxygen alarmsAnalog and relay outputsRemote corridor indicator

Planning a Oxygen Sensor specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto