Capteur d'oxygène par

A fixed electrochemical oxygen monitor that warns of oxygen depletion or enrichment near inert-gas and process-gas use areas.
  • Electrochemical O₂ Measurement
  • Local Concentration Display
  • Dual Alarm Relays
  • Replaceable Sensor Cell
Demander un devis. Browse les produits

Introduction de produit

The oxygen depletion sensor continuously samples surrounding air through a protected diffusion cap. An electrochemical cell produces a signal proportional to oxygen partial pressure, and internal electronics display the concentration and compare it with independent alarm thresholds. Local sounder and beacon functions can be supplemented by relay, current or digital outputs to a central alarm system. The replaceable cell and accessible calibration interface support planned maintenance without replacing the wall-mounted transmitter body.

Key Features

Diffusion-based electrochemical sensing requires no sample pump for normal room monitoring.

A bright local display shows oxygen concentration before and during an alarm condition.

Separate low and high alarm thresholds address depletion and enrichment risks.

Replaceable sensing cells extend transmitter service life and simplify maintenance planning.

Préoccupations du client produit

Oxygen hazards can develop without odor or visible warning, so room coverage, alarm visibility and sensor maintenance must be deliberate.

Inert-gas leakage displaces oxygen without giving occupants a sensory warning.Continuous oxygen measurement activates visible and audible alarms before entry or exposure continues.
A sensor mounted too high misses heavier or poorly mixed displacement patterns.Risk-based mounting positions place detectors near credible gas accumulation and breathing zones.
An aged electrochemical cell loses response gradually.Planned bump checks, calibration and replaceable cells maintain response confidence.
A local alarm is not seen from outside the room.Relay and network outputs drive corridor beacons, central annunciation and ventilation actions.

Les applications typiques

Nitrogen-supplied cleanroomsCryogenic storage support areasGas cabinet roomsLaboratory inert-gas zones

Paramètres techniques

Typical construction values for a fixed oxygen depletion sensor are listed below.

Matériaux de baseReplaceable electrochemical oxygen cell in polycarbonate transmitter with stainless protective sensor guard
Panneau épaisseur55-90 mm detector depth
Largeur effective110-180 mm housing width
Longueur maximaleUp to 240 mm detector height
Acier face épaisseur0.5-1.0 mm stainless sensor guard
Densité Core1180-1220 kg/m³ for polycarbonate transmitter body
Conductivité thermique0.19-0.22 W/(m·K) for polycarbonate enclosure material
surface finieWhite or safety-yellow housing with black display, green normal light and red alarm beacon
Type jointWall-mount base with diffusion sensor cap, cable gland and removable alarm terminals
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Local sounder and beaconLow and high oxygen alarmsAnalog and relay outputsRemote corridor indicator