Sensor oksigen

A fixed electrochemical oxygen monitor that warns of oxygen depletion or enrichment near inert-gas and process-gas use areas.
  • Electrochemical O₂ Measurement
  • Local Concentration Display
  • Dual Alarm Relays
  • Replaceable Sensor Cell
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The oxygen depletion sensor continuously samples surrounding air through a protected diffusion cap. An electrochemical cell produces a signal proportional to oxygen partial pressure, and internal electronics display the concentration and compare it with independent alarm thresholds. Local sounder and beacon functions can be supplemented by relay, current or digital outputs to a central alarm system. The replaceable cell and accessible calibration interface support planned maintenance without replacing the wall-mounted transmitter body.

Ciri-ciri Utama

Diffusion-based electrochemical sensing requires no sample pump for normal room monitoring.

A bright local display shows oxygen concentration before and during an alarm condition.

Separate low and high alarm thresholds address depletion and enrichment risks.

Replaceable sensing cells extend transmitter service life and simplify maintenance planning.

Kebimbangan Produk Pelanggan

Oxygen hazards can develop without odor or visible warning, so room coverage, alarm visibility and sensor maintenance must be deliberate.

Inert-gas leakage displaces oxygen without giving occupants a sensory warning.Continuous oxygen measurement activates visible and audible alarms before entry or exposure continues.
A sensor mounted too high misses heavier or poorly mixed displacement patterns.Risk-based mounting positions place detectors near credible gas accumulation and breathing zones.
An aged electrochemical cell loses response gradually.Planned bump checks, calibration and replaceable cells maintain response confidence.
A local alarm is not seen from outside the room.Relay and network outputs drive corridor beacons, central annunciation and ventilation actions.

Permohonan yang biasa

Nitrogen-supplied cleanroomsCryogenic storage support areasGas cabinet roomsLaboratory inert-gas zones

Parameter teknikal

Typical construction values for a fixed oxygen depletion sensor are listed below.

Bahan TerasReplaceable electrochemical oxygen cell in polycarbonate transmitter with stainless protective sensor guard
Ketebalan Panel55-90 mm detector depth
Lebar berkesan110-180 mm housing width
Panjang maksimumUp to 240 mm detector height
Keluli Menghadapi Ketebalan0.5-1.0 mm stainless sensor guard
Ketumpatan teras1180-1220 kg/m³ for polycarbonate transmitter body
Kekonduksian Terma0.19-0.22 W/(m·K) for polycarbonate enclosure material
Kemasan permukaanWhite or safety-yellow housing with black display, green normal light and red alarm beacon
Jenis BersatuWall-mount base with diffusion sensor cap, cable gland and removable alarm terminals
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Local sounder and beaconLow and high oxygen alarmsAnalog and relay outputsRemote corridor indicator