Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Sistema de Controle VAV

A pressure-independent variable air volume package that measures branch airflow and regulates a VAV damper across changing duct static pressure.
  • Pressure-Independent Airflow
  • Integrated Flow Measurement
  • Minimum and Maximum Limits
  • Networked Actuator Feedback
Solicite um orçamento. Browse produtos

Introdução do produto

The VAV control system integrates a differential pressure sensor, airflow calculation, controller and direct-coupled actuator on a factory-assembled terminal. It maintains the requested airflow even when upstream duct pressure varies within the operating range. Configurable minimum and maximum limits protect ventilation requirements and cap excessive branch flow. Supply, return and exhaust terminals can exchange airflow values with room pressure logic, while network communication exposes actual volume, setpoint, damper position and alarms to the supervisory system.

Características-chave

Pressure-independent control compensates for normal changes in upstream duct static pressure.

Factory-arranged sensor tubing and actuator linkage reduce field assembly variables.

Minimum and maximum airflow limits keep operation within the terminal's useful control range.

Network feedback reports actual airflow, requested airflow and damper position separately.

Preocupações do produto do cliente

A VAV branch must deliver stable air volume even as the main duct pressure changes with other terminal demands.

Airflow rises when other branches close and duct pressure increases.Pressure-independent measurement and damper control hold the requested branch volume.
A terminal cannot control accurately below its usable sensor range.Configured minimum airflow prevents operation in the unstable low-signal region.
Field-installed tubing is reversed or pinched during commissioning.Clearly identified high and low ports with short factory-routed tubing reduce connection errors.
The BMS sees actuator position but cannot verify delivered air volume.Independent airflow feedback confirms actual branch performance rather than inferred damper movement.

Aplicações típicas

Cleanroom supply-air terminalsLaboratory exhaust branchesAirlock transfer airflowVariable-occupancy controlled rooms

Parâmetros técnicos

Typical materials and dimensions for a pressure-independent cleanroom VAV terminal are shown below.

Material principalGalvanized steel VAV casing with aluminum sensing cross, polymer controller and copper motor windings
Painel de espessura180-450 mm terminal depth
Largura efetiva150-800 mm nominal duct width or diameter
Comprimento máximoUp to 1200 mm terminal assembly length
Aço enfrentando espessura0.8-1.2 mm galvanized steel casing
Densidade Core7800-8050 kg/m³ for steel casing and damper components
Condutividade térmica45-60 W/(m·K) for galvanized steel structural parts
Superfície acabadoClean zinc-coated steel casing with white controller and blue or orange actuator accent
Tipo conjuntoCircular spigot or rectangular flange with integral averaging pickup and direct-coupled actuator
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Circular or rectangular terminalSupply, return or exhaust dutySpring-return actuatorBACnet MS/TP or Modbus RTU