Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Kontrol Cleanroom dan Sistem Pemantauan Lingkungan

Sistem Kontrol VAV

A pressure-independent variable air volume package that measures branch airflow and regulates a VAV damper across changing duct static pressure.
  • Pressure-Independent Airflow
  • Integrated Flow Measurement
  • Minimum and Maximum Limits
  • Networked Actuator Feedback
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The VAV control system integrates a differential pressure sensor, airflow calculation, controller and direct-coupled actuator on a factory-assembled terminal. It maintains the requested airflow even when upstream duct pressure varies within the operating range. Configurable minimum and maximum limits protect ventilation requirements and cap excessive branch flow. Supply, return and exhaust terminals can exchange airflow values with room pressure logic, while network communication exposes actual volume, setpoint, damper position and alarms to the supervisory system.

Fitur utama:

Pressure-independent control compensates for normal changes in upstream duct static pressure.

Factory-arranged sensor tubing and actuator linkage reduce field assembly variables.

Minimum and maximum airflow limits keep operation within the terminal's useful control range.

Network feedback reports actual airflow, requested airflow and damper position separately.

Kekhawatiran produk pelanggan

A VAV branch must deliver stable air volume even as the main duct pressure changes with other terminal demands.

Airflow rises when other branches close and duct pressure increases.Pressure-independent measurement and damper control hold the requested branch volume.
A terminal cannot control accurately below its usable sensor range.Configured minimum airflow prevents operation in the unstable low-signal region.
Field-installed tubing is reversed or pinched during commissioning.Clearly identified high and low ports with short factory-routed tubing reduce connection errors.
The BMS sees actuator position but cannot verify delivered air volume.Independent airflow feedback confirms actual branch performance rather than inferred damper movement.

Aplikasi yang Tipis

Cleanroom supply-air terminalsLaboratory exhaust branchesAirlock transfer airflowVariable-occupancy controlled rooms

Parameter teknis

Typical materials and dimensions for a pressure-independent cleanroom VAV terminal are shown below.

Bahan intiGalvanized steel VAV casing with aluminum sensing cross, polymer controller and copper motor windings
Ketebalan Panel (Panel Thickness)180-450 mm terminal depth
Efektif lebar150-800 mm nominal duct width or diameter
Panjang maksimumUp to 1200 mm terminal assembly length
Baja menghadap ketebalan0.8-1.2 mm galvanized steel casing
Kepadatan inti (core density)7800-8050 kg/m³ for steel casing and damper components
Konduktivitas Termal (Thermal Conductivity)45-60 W/(m·K) for galvanized steel structural parts
Permukaan selesaiClean zinc-coated steel casing with white controller and blue or orange actuator accent
Jenis BersamaCircular spigot or rectangular flange with integral averaging pickup and direct-coupled actuator
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Circular or rectangular terminalSupply, return or exhaust dutySpring-return actuatorBACnet MS/TP or Modbus RTU

Planning a VAV Control System specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami