A pressure-independent variable air volume package that measures branch airflow and regulates a VAV damper across changing duct static pressure.
  • Pressure-Independent Airflow
  • Integrated Flow Measurement
  • Minimum and Maximum Limits
  • Networked Actuator Feedback
見積もりリクエスト 製品案内

商品紹介

The VAV control system integrates a differential pressure sensor, airflow calculation, controller and direct-coupled actuator on a factory-assembled terminal. It maintains the requested airflow even when upstream duct pressure varies within the operating range. Configurable minimum and maximum limits protect ventilation requirements and cap excessive branch flow. Supply, return and exhaust terminals can exchange airflow values with room pressure logic, while network communication exposes actual volume, setpoint, damper position and alarms to the supervisory system.

主要な特徴

Pressure-independent control compensates for normal changes in upstream duct static pressure.

Factory-arranged sensor tubing and actuator linkage reduce field assembly variables.

Minimum and maximum airflow limits keep operation within the terminal's useful control range.

Network feedback reports actual airflow, requested airflow and damper position separately.

お客様の製品に関する懸念事項

A VAV branch must deliver stable air volume even as the main duct pressure changes with other terminal demands.

Airflow rises when other branches close and duct pressure increases.Pressure-independent measurement and damper control hold the requested branch volume.
A terminal cannot control accurately below its usable sensor range.Configured minimum airflow prevents operation in the unstable low-signal region.
Field-installed tubing is reversed or pinched during commissioning.Clearly identified high and low ports with short factory-routed tubing reduce connection errors.
The BMS sees actuator position but cannot verify delivered air volume.Independent airflow feedback confirms actual branch performance rather than inferred damper movement.

典型的な用途

Cleanroom supply-air terminalsLaboratory exhaust branchesAirlock transfer airflowVariable-occupancy controlled rooms

技術的なパラメータ

Typical materials and dimensions for a pressure-independent cleanroom VAV terminal are shown below.

コア材料Galvanized steel VAV casing with aluminum sensing cross, polymer controller and copper motor windings
パネルの厚さ180-450 mm terminal depth
有効幅150-800 mm nominal duct width or diameter
最大長さUp to 1200 mm terminal assembly length
鋼鉄の厚さを直面する0.8-1.2 mm galvanized steel casing
コア密度7800-8050 kg/m³ for steel casing and damper components
熱伝導率45-60 W/(m·K) for galvanized steel structural parts
表面仕上げClean zinc-coated steel casing with white controller and blue or orange actuator accent
ジョイントタイプCircular spigot or rectangular flange with integral averaging pickup and direct-coupled actuator
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Circular or rectangular terminalSupply, return or exhaust dutySpring-return actuatorBACnet MS/TP or Modbus RTU