클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

VAV 제어 시스템

A pressure-independent variable air volume package that measures branch airflow and regulates a VAV damper across changing duct static pressure.
  • Pressure-Independent Airflow
  • Integrated Flow Measurement
  • Minimum and Maximum Limits
  • Networked Actuator Feedback
견적 요청 제품 찾아보기

상품 소개

The VAV control system integrates a differential pressure sensor, airflow calculation, controller and direct-coupled actuator on a factory-assembled terminal. It maintains the requested airflow even when upstream duct pressure varies within the operating range. Configurable minimum and maximum limits protect ventilation requirements and cap excessive branch flow. Supply, return and exhaust terminals can exchange airflow values with room pressure logic, while network communication exposes actual volume, setpoint, damper position and alarms to the supervisory system.

주요 기능

Pressure-independent control compensates for normal changes in upstream duct static pressure.

Factory-arranged sensor tubing and actuator linkage reduce field assembly variables.

Minimum and maximum airflow limits keep operation within the terminal's useful control range.

Network feedback reports actual airflow, requested airflow and damper position separately.

고객 제품 관심사

A VAV branch must deliver stable air volume even as the main duct pressure changes with other terminal demands.

Airflow rises when other branches close and duct pressure increases.Pressure-independent measurement and damper control hold the requested branch volume.
A terminal cannot control accurately below its usable sensor range.Configured minimum airflow prevents operation in the unstable low-signal region.
Field-installed tubing is reversed or pinched during commissioning.Clearly identified high and low ports with short factory-routed tubing reduce connection errors.
The BMS sees actuator position but cannot verify delivered air volume.Independent airflow feedback confirms actual branch performance rather than inferred damper movement.

일반적인 응용 프로그램

Cleanroom supply-air terminalsLaboratory exhaust branchesAirlock transfer airflowVariable-occupancy controlled rooms

기술 매개변수

Typical materials and dimensions for a pressure-independent cleanroom VAV terminal are shown below.

핵심 재료Galvanized steel VAV casing with aluminum sensing cross, polymer controller and copper motor windings
패널 두께180-450 mm terminal depth
유효 폭150-800 mm nominal duct width or diameter
최대 길이Up to 1200 mm terminal assembly length
강철 면면 두께0.8-1.2 mm galvanized steel casing
코어 밀도7800-8050 kg/m³ for steel casing and damper components
열전도도 (Thermal Conductivity)45-60 W/(m·K) for galvanized steel structural parts
표면 마무리Clean zinc-coated steel casing with white controller and blue or orange actuator accent
접합 유형Circular spigot or rectangular flange with integral averaging pickup and direct-coupled actuator
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Circular or rectangular terminalSupply, return or exhaust dutySpring-return actuatorBACnet MS/TP or Modbus RTU

Planning a VAV Control System specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat