Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Kontrolü ve Çevre İzleme Sistemleri

VAV Kontrol Sistemi

A pressure-independent variable air volume package that measures branch airflow and regulates a VAV damper across changing duct static pressure.
  • Pressure-Independent Airflow
  • Integrated Flow Measurement
  • Minimum and Maximum Limits
  • Networked Actuator Feedback
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The VAV control system integrates a differential pressure sensor, airflow calculation, controller and direct-coupled actuator on a factory-assembled terminal. It maintains the requested airflow even when upstream duct pressure varies within the operating range. Configurable minimum and maximum limits protect ventilation requirements and cap excessive branch flow. Supply, return and exhaust terminals can exchange airflow values with room pressure logic, while network communication exposes actual volume, setpoint, damper position and alarms to the supervisory system.

Ana Özellikler

Pressure-independent control compensates for normal changes in upstream duct static pressure.

Factory-arranged sensor tubing and actuator linkage reduce field assembly variables.

Minimum and maximum airflow limits keep operation within the terminal's useful control range.

Network feedback reports actual airflow, requested airflow and damper position separately.

Müşteri Ürün Sorunları

A VAV branch must deliver stable air volume even as the main duct pressure changes with other terminal demands.

Airflow rises when other branches close and duct pressure increases.Pressure-independent measurement and damper control hold the requested branch volume.
A terminal cannot control accurately below its usable sensor range.Configured minimum airflow prevents operation in the unstable low-signal region.
Field-installed tubing is reversed or pinched during commissioning.Clearly identified high and low ports with short factory-routed tubing reduce connection errors.
The BMS sees actuator position but cannot verify delivered air volume.Independent airflow feedback confirms actual branch performance rather than inferred damper movement.

Tipik uygulamalar

Cleanroom supply-air terminalsLaboratory exhaust branchesAirlock transfer airflowVariable-occupancy controlled rooms

Teknik parametreler

Typical materials and dimensions for a pressure-independent cleanroom VAV terminal are shown below.

Temel malzemelerGalvanized steel VAV casing with aluminum sensing cross, polymer controller and copper motor windings
Panel kalınlığı180-450 mm terminal depth
Effective Width (Etkili Genişlik)150-800 mm nominal duct width or diameter
Maksimum uzunlukUp to 1200 mm terminal assembly length
Çelik yüz yüze kalınlığı0.8-1.2 mm galvanized steel casing
Core Density (Çekirdek Yoğunluğu)7800-8050 kg/m³ for steel casing and damper components
Termal İletkenlik45-60 W/(m·K) for galvanized steel structural parts
Yüzey bitirmeClean zinc-coated steel casing with white controller and blue or orange actuator accent
Ortak tipCircular spigot or rectangular flange with integral averaging pickup and direct-coupled actuator
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Circular or rectangular terminalSupply, return or exhaust dutySpring-return actuatorBACnet MS/TP or Modbus RTU

Planning a VAV Control System specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim