Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Equipamentos de drenagem, higiene e segurança da sala limpa

Z Monitor de deficiência de oxigênio

A fixed oxygen monitor that warns occupants and ventilation controls when inert gas displaces breathable air.
  • Continuous Oxygen Display
  • Low-Oxygen Alarm Stages
  • Local Beacon and Sounder
  • Ventilation Relay Output
Solicite um orçamento. Browse produtos

Introdução do produto

The oxygen deficiency monitor continuously measures ambient oxygen with a replaceable electrochemical or optical sensor and presents the value on a local display. Configurable low-level alarms operate relays, beacon and sounder outputs before conditions become severe. Remote heads can be positioned at the breathing zone or according to the release scenario while the display remains visible outside the room.

Características-chave

Continuous oxygen indication gives personnel an immediate room-status check.

Two alarm stages support ventilation and evacuation actions.

Sensor and system faults are separated from gas alarms.

Remote outputs integrate with ventilation and access-control logic.

Preocupações do produto do cliente

Inert gases are odorless and can displace oxygen without visible warning, especially in enclosed utility spaces.

Personnel cannot sense oxygen depletion directly.A fixed sensor continuously measures and displays oxygen concentration.
A single high alarm provides little time for corrective action.Staged low alarms can start ventilation before evacuation level.
Sensor end-of-life can mimic a safe reading.Fault monitoring and scheduled replacement maintain measurement integrity.
The safest display location may differ from the sensing point.Remote-sensor configurations separate the room sensor from the entrance display.

Aplicações típicas

Nitrogen utility roomsCryogenic storage areasInert-gas process suitesLaboratory gas storage

Parâmetros técnicos

Typical monitor construction is listed below; sensor placement and alarm setpoints follow the inert-gas risk assessment.

Material principalPowder-coated steel or polymer enclosure with oxygen sensor electronics
Painel de espessura1.0-1.5 mm metal enclosure
Largura efetiva150-300 mm
Comprimento máximoUp to 450 mm enclosure height
Aço enfrentando espessura1.0-1.5 mm steel enclosure panels
Densidade Core7850 kg/m³ for steel enclosure parts
Condutividade térmica45-60 W/(m·K) for steel enclosure components
Superfície acabadoSmooth light-gray coating with high-visibility alarm indicators
Tipo conjuntoGasketed enclosure with pluggable sensor, relay and power terminals
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Integral or remote sensorDual alarm relaysBeacon and sounderAnalog or network output

Planning a Oxygen Deficiency Monitor specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat