A fixed oxygen monitor that warns occupants and ventilation controls when inert gas displaces breathable air.
  • Continuous Oxygen Display
  • Low-Oxygen Alarm Stages
  • Local Beacon and Sounder
  • Ventilation Relay Output
Solicite un presupuesto. Browse productos

Introducción del producto

The oxygen deficiency monitor continuously measures ambient oxygen with a replaceable electrochemical or optical sensor and presents the value on a local display. Configurable low-level alarms operate relays, beacon and sounder outputs before conditions become severe. Remote heads can be positioned at the breathing zone or according to the release scenario while the display remains visible outside the room.

Características clave

Continuous oxygen indication gives personnel an immediate room-status check.

Two alarm stages support ventilation and evacuation actions.

Sensor and system faults are separated from gas alarms.

Remote outputs integrate with ventilation and access-control logic.

Preocupaciones del producto del cliente

Inert gases are odorless and can displace oxygen without visible warning, especially in enclosed utility spaces.

Personnel cannot sense oxygen depletion directly.A fixed sensor continuously measures and displays oxygen concentration.
A single high alarm provides little time for corrective action.Staged low alarms can start ventilation before evacuation level.
Sensor end-of-life can mimic a safe reading.Fault monitoring and scheduled replacement maintain measurement integrity.
The safest display location may differ from the sensing point.Remote-sensor configurations separate the room sensor from the entrance display.

Aplicaciones típicas

Nitrogen utility roomsCryogenic storage areasInert-gas process suitesLaboratory gas storage

Parámetros técnicos

Typical monitor construction is listed below; sensor placement and alarm setpoints follow the inert-gas risk assessment.

Materiales CorePowder-coated steel or polymer enclosure with oxygen sensor electronics
Panel de espesor1.0-1.5 mm metal enclosure
Ancho efectivo150-300 mm
Longitud máximaUp to 450 mm enclosure height
Acero frente a espesor1.0-1.5 mm steel enclosure panels
Densidad Core7850 kg/m³ for steel enclosure parts
Conductividad térmica45-60 W/(m·K) for steel enclosure components
Superficie acabadaSmooth light-gray coating with high-visibility alarm indicators
Tipo conjuntoGasketed enclosure with pluggable sensor, relay and power terminals
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Integral or remote sensorDual alarm relaysBeacon and sounderAnalog or network output