Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Drainage de salle blanche, équipement d'hygiène et de sécurité

Z Moniteur de carence en oxygène

A fixed oxygen monitor that warns occupants and ventilation controls when inert gas displaces breathable air.
  • Continuous Oxygen Display
  • Low-Oxygen Alarm Stages
  • Local Beacon and Sounder
  • Ventilation Relay Output
Demander un devis. Browse les produits

Introduction de produit

The oxygen deficiency monitor continuously measures ambient oxygen with a replaceable electrochemical or optical sensor and presents the value on a local display. Configurable low-level alarms operate relays, beacon and sounder outputs before conditions become severe. Remote heads can be positioned at the breathing zone or according to the release scenario while the display remains visible outside the room.

Key Features

Continuous oxygen indication gives personnel an immediate room-status check.

Two alarm stages support ventilation and evacuation actions.

Sensor and system faults are separated from gas alarms.

Remote outputs integrate with ventilation and access-control logic.

Préoccupations du client produit

Inert gases are odorless and can displace oxygen without visible warning, especially in enclosed utility spaces.

Personnel cannot sense oxygen depletion directly.A fixed sensor continuously measures and displays oxygen concentration.
A single high alarm provides little time for corrective action.Staged low alarms can start ventilation before evacuation level.
Sensor end-of-life can mimic a safe reading.Fault monitoring and scheduled replacement maintain measurement integrity.
The safest display location may differ from the sensing point.Remote-sensor configurations separate the room sensor from the entrance display.

Les applications typiques

Nitrogen utility roomsCryogenic storage areasInert-gas process suitesLaboratory gas storage

Paramètres techniques

Typical monitor construction is listed below; sensor placement and alarm setpoints follow the inert-gas risk assessment.

Matériaux de basePowder-coated steel or polymer enclosure with oxygen sensor electronics
Panneau épaisseur1.0-1.5 mm metal enclosure
Largeur effective150-300 mm
Longueur maximaleUp to 450 mm enclosure height
Acier face épaisseur1.0-1.5 mm steel enclosure panels
Densité Core7850 kg/m³ for steel enclosure parts
Conductivité thermique45-60 W/(m·K) for steel enclosure components
surface finieSmooth light-gray coating with high-visibility alarm indicators
Type jointGasketed enclosure with pluggable sensor, relay and power terminals
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Integral or remote sensorDual alarm relaysBeacon and sounderAnalog or network output

Planning a Oxygen Deficiency Monitor specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact