Sistema de barreira de acesso restrito aberto
- Rigid Operator Separation
- HEPA-Filtered Critical Downflow
- Glove-Assisted Interventions
- Open RABS Cleanroom Interface
Introdução do produto
An open RABS surrounds the critical filling or handling zone with rigid transparent panels and glove-access doors while remaining dependent on the background cleanroom. Filtered unidirectional air protects open product locations, and operators perform routine interventions through fixed gloves instead of opening the barrier. The enclosure is not gas-tight and does not use a sealed pressure shell; planned door openings, setup and cleaning follow the surrounding cleanroom procedure.
Características-chave
Glove ports support planned interventions without opening access doors.
HEPA-filtered downflow maintains first air over open containers and closures.
Hinged barrier doors provide controlled setup and maintenance access.
The modular frame integrates around existing filling equipment and conveyors.
Preocupações do produto do cliente
An open RABS reduces operator intervention but still relies on the surrounding cleanroom and disciplined door-opening control.
Aplicações típicas
Parâmetros técnicos
Typical configurable construction ranges for an open restricted access barrier system are listed below.
| Material principal | SUS304 or SUS316L modular frame with laminated safety-glass panels and CSM glove assemblies |
|---|---|
| Painel de espessura | 30-60 mm framed barrier and lower-skirt sections |
| Largura efetiva | 1500-5000 mm protected line width |
| Comprimento máximo | Up to 20000 mm modular barrier length |
| Aço enfrentando espessura | 1.2-2.0 mm stainless lower skirts and service panels |
| Densidade Core | Approximately 2500 kg/m³ for laminated safety-glass barrier panels |
| Condutividade térmica | 0.8-1.0 W/(m·K) for laminated safety glass |
| Superfície acabado | Fine-brushed stainless frame with flush clear laminated glazing |
| Tipo conjunto | Bolted modular barrier frame with gasketed glazing, hinged glove doors and sealed machine skirts |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Open Restricted Access Barrier System specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã