Z Système de barrière d'accès restreint ouvert
- Rigid Operator Separation
- HEPA-Filtered Critical Downflow
- Glove-Assisted Interventions
- Open RABS Cleanroom Interface
Introduction de produit
An open RABS surrounds the critical filling or handling zone with rigid transparent panels and glove-access doors while remaining dependent on the background cleanroom. Filtered unidirectional air protects open product locations, and operators perform routine interventions through fixed gloves instead of opening the barrier. The enclosure is not gas-tight and does not use a sealed pressure shell; planned door openings, setup and cleaning follow the surrounding cleanroom procedure.
Key Features
Glove ports support planned interventions without opening access doors.
HEPA-filtered downflow maintains first air over open containers and closures.
Hinged barrier doors provide controlled setup and maintenance access.
The modular frame integrates around existing filling equipment and conveyors.
Préoccupations du client produit
An open RABS reduces operator intervention but still relies on the surrounding cleanroom and disciplined door-opening control.
Les applications typiques
Paramètres techniques
Typical configurable construction ranges for an open restricted access barrier system are listed below.
| Matériaux de base | SUS304 or SUS316L modular frame with laminated safety-glass panels and CSM glove assemblies |
|---|---|
| Panneau épaisseur | 30-60 mm framed barrier and lower-skirt sections |
| Largeur effective | 1500-5000 mm protected line width |
| Longueur maximale | Up to 20000 mm modular barrier length |
| Acier face épaisseur | 1.2-2.0 mm stainless lower skirts and service panels |
| Densité Core | Approximately 2500 kg/m³ for laminated safety-glass barrier panels |
| Conductivité thermique | 0.8-1.0 W/(m·K) for laminated safety glass |
| surface finie | Fine-brushed stainless frame with flush clear laminated glazing |
| Type joint | Bolted modular barrier frame with gasketed glazing, hinged glove doors and sealed machine skirts |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Open Restricted Access Barrier System specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien