A rigid open RABS that limits direct operator access to an aseptic line through transparent panels, glove ports and controlled HEPA-filtered downflow.
  • Rigid Operator Separation
  • HEPA-Filtered Critical Downflow
  • Glove-Assisted Interventions
  • Open RABS Cleanroom Interface
Solicite un presupuesto. Browse productos

Introducción del producto

An open RABS surrounds the critical filling or handling zone with rigid transparent panels and glove-access doors while remaining dependent on the background cleanroom. Filtered unidirectional air protects open product locations, and operators perform routine interventions through fixed gloves instead of opening the barrier. The enclosure is not gas-tight and does not use a sealed pressure shell; planned door openings, setup and cleaning follow the surrounding cleanroom procedure.

Características clave

Rigid glazed panels reduce direct operator contact with the critical line.

Glove ports support planned interventions without opening access doors.

HEPA-filtered downflow maintains first air over open containers and closures.

Hinged barrier doors provide controlled setup and maintenance access.

The modular frame integrates around existing filling equipment and conveyors.

Preocupaciones del producto del cliente

An open RABS reduces operator intervention but still relies on the surrounding cleanroom and disciplined door-opening control.

Operators reach directly over open sterile containers.Glove ports position routine interventions outside the open product path.
Barrier panels obstruct machine controls and jam points.Door, glove and control locations are mapped to actual intervention positions.
Users treat an open RABS like a sealed isolator.The open-system dependency on the background cleanroom is stated in operation and layout guidance.
Panel joints create ledges beside the conveyor.Flush framed glazing and sealed lower skirts reduce exposed horizontal edges.

Aplicaciones típicas

Aseptic vial fillingOpen-container transferStopper feeding protectionSterile component handling in cleanrooms

Parámetros técnicos

Typical configurable construction ranges for an open restricted access barrier system are listed below.

Materiales CoreSUS304 or SUS316L modular frame with laminated safety-glass panels and CSM glove assemblies
Panel de espesor30-60 mm framed barrier and lower-skirt sections
Ancho efectivo1500-5000 mm protected line width
Longitud máximaUp to 20000 mm modular barrier length
Acero frente a espesor1.2-2.0 mm stainless lower skirts and service panels
Densidad CoreApproximately 2500 kg/m³ for laminated safety-glass barrier panels
Conductividad térmica0.8-1.0 W/(m·K) for laminated safety glass
Superficie acabadaFine-brushed stainless frame with flush clear laminated glazing
Tipo conjuntoBolted modular barrier frame with gasketed glazing, hinged glove doors and sealed machine skirts
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Active overhead HEPA supplyFixed or hinged glove panelsMachine and conveyor cut-outsEnvironmental monitoring ports