Gabinete seco de baixa umidade
- Active molecular-sieve drying modules
- Adjustable 1–10% RH setpoint range
- Static-dissipative glazed doors
- Digital humidity display and alarms
Introdução do produto
The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.
Características-chave
Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.
A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.
The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.
Preocupações do produto do cliente
Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.
Aplicações típicas
Parâmetros técnicos
Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.
| Material principal | Powder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules |
|---|---|
| Painel de espessura | 1.2 mm enclosure panels, door frames and rear air-distribution channel |
| Largura efetiva | 1200 mm overall cabinet width |
| Comprimento máximo | 1900 mm maximum overall cabinet height |
| Aço enfrentando espessura | 1.2 mm powder-coated carbon-steel body, doors and shelf supports |
| Densidade Core | 7850 kg/m³ for the carbon-steel enclosure |
| Condutividade térmica | 45–60 W/(m·K) for the carbon-steel enclosure |
| Superfície acabado | Light-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves |
| Tipo conjunto | Seam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis