Cabinet sec à faible humidité
- Active molecular-sieve drying modules
- Adjustable 1–10% RH setpoint range
- Static-dissipative glazed doors
- Digital humidity display and alarms
Introduction de produit
The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.
Key Features
Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.
A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.
The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.
Préoccupations du client produit
Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.
Les applications typiques
Paramètres techniques
Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.
| Matériaux de base | Powder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules |
|---|---|
| Panneau épaisseur | 1.2 mm enclosure panels, door frames and rear air-distribution channel |
| Largeur effective | 1200 mm overall cabinet width |
| Longueur maximale | 1900 mm maximum overall cabinet height |
| Acier face épaisseur | 1.2 mm powder-coated carbon-steel body, doors and shelf supports |
| Densité Core | 7850 kg/m³ for the carbon-steel enclosure |
| Conductivité thermique | 45–60 W/(m·K) for the carbon-steel enclosure |
| surface finie | Light-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves |
| Type joint | Seam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Low-Humidity Dry Cabinet specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien