Kabinet Kering Rendah Kelembapan
- Active molecular-sieve drying modules
- Adjustable 1–10% RH setpoint range
- Static-dissipative glazed doors
- Digital humidity display and alarms
Pengenalan Produk
The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.
Ciri-ciri Utama
Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.
A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.
The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.
Kebimbangan Produk Pelanggan
Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.
Permohonan yang biasa
Parameter teknikal
Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.
| Bahan Teras | Powder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules |
|---|---|
| Ketebalan Panel | 1.2 mm enclosure panels, door frames and rear air-distribution channel |
| Lebar berkesan | 1200 mm overall cabinet width |
| Panjang maksimum | 1900 mm maximum overall cabinet height |
| Keluli Menghadapi Ketebalan | 1.2 mm powder-coated carbon-steel body, doors and shelf supports |
| Ketumpatan teras | 7850 kg/m³ for the carbon-steel enclosure |
| Kekonduksian Terma | 45–60 W/(m·K) for the carbon-steel enclosure |
| Kemasan permukaan | Light-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves |
| Jenis Bersatu | Seam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Low-Humidity Dry Cabinet specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)