موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أثاث الغرف النظيفة ومنتجات الفولاذ المقاوم للصدأ

خفضة الرطوبة الجاف مجلس الوزراء

An actively controlled steel dry cabinet that uses automatically regenerated molecular-sieve modules to maintain a stable low-humidity atmosphere around moisture-sensitive components.
  • Active molecular-sieve drying modules
  • Adjustable 1–10% RH setpoint range
  • Static-dissipative glazed doors
  • Digital humidity display and alarms
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.

الخصائص الرئيسية

Alternating molecular-sieve modules regenerate automatically, allowing one drying path to remain available while the other restores its moisture capacity.

Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.

A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.

The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.

مخاوف المنتج للعملاء

Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.

Moisture-sensitive packages absorb room humidity between assembly operations.Active molecular-sieve modules continuously remove water vapor and return dry air through the rear distribution channel.
Opening one full-height door raises humidity around every stored reel and tray.Three independently gasketed glazed zones confine each access event to a smaller cabinet volume.
A saturated desiccant pack can stop protecting stock without a visible warning.Automatic regeneration and the external RH controller expose drying status and high-humidity conditions at the front panel.
Very dry air increases the static sensitivity of ungrounded component storage.Conductive shelf supports, static-dissipative glazing and an external grounding stud create a controlled discharge path.

تطبيقات نموذجية

Moisture-sensitive semiconductor package storagePrinted circuit board stagingPrecision sensor and optical component holdingAdditive-manufacturing powder container storageElectronic assembly work-in-process protection

المعلمات الفنية

Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.

المواد الأساسيةPowder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules
سمك اللوحة1.2 mm enclosure panels, door frames and rear air-distribution channel
العرض الفعال1200 mm overall cabinet width
الحد الأقصى الطول1900 mm maximum overall cabinet height
الصلب يواجه سمك1.2 mm powder-coated carbon-steel body, doors and shelf supports
الكثافة الأساسية7850 kg/m³ for the carbon-steel enclosure
الموصلية الحرارية45–60 W/(m·K) for the carbon-steel enclosure
إنهاء السطحLight-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves
نوع المشتركSeam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

1–10% RH or 10–20% RH control rangesTemperature and RH data loggingReel-support or pull-out tray packagesNitrogen backup purge connection