Düşük nemli kuru kabine
- Active molecular-sieve drying modules
- Adjustable 1–10% RH setpoint range
- Static-dissipative glazed doors
- Digital humidity display and alarms
Ürün tanıtımı
The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.
Ana Özellikler
Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.
A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.
The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.
Müşteri Ürün Sorunları
Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.
Tipik uygulamalar
Teknik parametreler
Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.
| Temel malzemeler | Powder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules |
|---|---|
| Panel kalınlığı | 1.2 mm enclosure panels, door frames and rear air-distribution channel |
| Effective Width (Etkili Genişlik) | 1200 mm overall cabinet width |
| Maksimum uzunluk | 1900 mm maximum overall cabinet height |
| Çelik yüz yüze kalınlığı | 1.2 mm powder-coated carbon-steel body, doors and shelf supports |
| Core Density (Çekirdek Yoğunluğu) | 7850 kg/m³ for the carbon-steel enclosure |
| Termal İletkenlik | 45–60 W/(m·K) for the carbon-steel enclosure |
| Yüzey bitirme | Light-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves |
| Ortak tip | Seam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Low-Humidity Dry Cabinet specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca