Painel de visão de sala limpa resistente ao fogo
- Specialist Fire-Glass Core
- Flush Protective Outer Panes
- Concealed Steel Subframe
- Assembly-Based Configuration
Introdução do produto
The fire-resistant vision panel is built as a complete glazing-and-frame assembly rather than by substituting a pane into a standard cleanroom window. A specialist fire-glass layer is protected by toughened outer panes, retained within a steel or stainless-steel subframe and finished flush to the cleanroom surfaces. Glass type, edge cover, seal materials, opening size and wall construction are selected together so the supplied configuration can match the documented fire strategy without sacrificing cleanability.
Características-chave
A concealed metal subframe supports the heavier glazing stack and maintains defined edge cover.
Screen-printed borders hide fire-compatible seals and mechanical retention from the room face.
Mullions and alternative glazing makeups allow the assembly to address different opening sizes and insulation needs.
Preocupações do produto do cliente
Fire performance depends on the complete wall, frame, seal and glazing construction, while the cleanroom-facing surfaces must remain flush and accessible for cleaning.
Aplicações típicas
Parâmetros técnicos
The ranges below describe common cleanroom fire-vision constructions; any declared fire performance applies only to the corresponding documented assembly.
| Material principal | Specialist clear fire-resistant glass protected by toughened safety-glass outer panes |
|---|---|
| Painel de espessura | 30–70 mm glazing stack; typically 75–150 mm overall frame depth |
| Largura efetiva | 300–1200 mm clear viewing width for common single-light assemblies |
| Comprimento máximo | 2400 mm overall window height, subject to the selected documented construction |
| Aço enfrentando espessura | 1.2–2.0 mm stainless or galvanized-steel subframe and liners |
| Densidade Core | Configuration-dependent multi-layer glass; typically 2500–3000 kg/m³ |
| Condutividade térmica | Approximately 0.3–1.0 W/(m·K), depending on the selected fire-glass composition |
| Superfície acabado | Flush clear toughened outer glass with bonded ceramic-frit border and brushed stainless trim |
| Tipo conjunto | Mechanically retained fire-glass assembly with fire-compatible seals and concealed subframe |
| Customização | Disponível com base na aplicação pretendida e ambiente operacional |
Opções disponíveis
Planning a Fire-Resistant Cleanroom Vision Panel specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã