A flush specialist glazing assembly combining fire-resisting glass, protective outer panes and a concealed metal frame for observation openings in fire-resisting cleanroom walls.
  • Specialist Fire-Glass Core
  • Flush Protective Outer Panes
  • Concealed Steel Subframe
  • Assembly-Based Configuration
見積もりリクエスト 製品案内

商品紹介

The fire-resistant vision panel is built as a complete glazing-and-frame assembly rather than by substituting a pane into a standard cleanroom window. A specialist fire-glass layer is protected by toughened outer panes, retained within a steel or stainless-steel subframe and finished flush to the cleanroom surfaces. Glass type, edge cover, seal materials, opening size and wall construction are selected together so the supplied configuration can match the documented fire strategy without sacrificing cleanability.

主要な特徴

The specialist fire-glass layer is isolated behind flush outer safety panes for routine cleaning.

A concealed metal subframe supports the heavier glazing stack and maintains defined edge cover.

Screen-printed borders hide fire-compatible seals and mechanical retention from the room face.

Mullions and alternative glazing makeups allow the assembly to address different opening sizes and insulation needs.

お客様の製品に関する懸念事項

Fire performance depends on the complete wall, frame, seal and glazing construction, while the cleanroom-facing surfaces must remain flush and accessible for cleaning.

A standard vision pane can become the weakest point in a fire-resisting partition.The opening uses a purpose-designed fire-glass stack and retained subframe matched to the intended wall construction.
Fire-compatible retainers often project into the clean area.Protective outer panes and opaque borders conceal the retention system behind flush room faces.
Large openings increase glass weight and edge stress.Opening dimensions, mullions and frame support are selected with the specific glazing makeup rather than treated as a standard window size.

典型的な用途

Fire-resisting pharmaceutical corridorsLaboratory compartment wallsHospital clean-area boundariesHazardous process observation points

技術的なパラメータ

The ranges below describe common cleanroom fire-vision constructions; any declared fire performance applies only to the corresponding documented assembly.

コア材料Specialist clear fire-resistant glass protected by toughened safety-glass outer panes
パネルの厚さ30–70 mm glazing stack; typically 75–150 mm overall frame depth
有効幅300–1200 mm clear viewing width for common single-light assemblies
最大長さ2400 mm overall window height, subject to the selected documented construction
鋼鉄の厚さを直面する1.2–2.0 mm stainless or galvanized-steel subframe and liners
コア密度Configuration-dependent multi-layer glass; typically 2500–3000 kg/m³
熱伝導率Approximately 0.3–1.0 W/(m·K), depending on the selected fire-glass composition
表面仕上げFlush clear toughened outer glass with bonded ceramic-frit border and brushed stainless trim
ジョイントタイプMechanically retained fire-glass assembly with fire-compatible seals and concealed subframe
カスタマイズ目的のアプリケーションおよび動作環境に基づいて利用可能

利用可能なオプション

Integrity-only or insulated glazing makeup304 or 316 stainless-steel trimMullioned larger openingIntegral blind where compatible

Planning a Fire-Resistant Cleanroom Vision Panel specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する