Fire-مقاومة لوحة الرؤية غرف نظيفة
- Specialist Fire-Glass Core
- Flush Protective Outer Panes
- Concealed Steel Subframe
- Assembly-Based Configuration
مقدمة المنتج
The fire-resistant vision panel is built as a complete glazing-and-frame assembly rather than by substituting a pane into a standard cleanroom window. A specialist fire-glass layer is protected by toughened outer panes, retained within a steel or stainless-steel subframe and finished flush to the cleanroom surfaces. Glass type, edge cover, seal materials, opening size and wall construction are selected together so the supplied configuration can match the documented fire strategy without sacrificing cleanability.
الخصائص الرئيسية
A concealed metal subframe supports the heavier glazing stack and maintains defined edge cover.
Screen-printed borders hide fire-compatible seals and mechanical retention from the room face.
Mullions and alternative glazing makeups allow the assembly to address different opening sizes and insulation needs.
مخاوف المنتج للعملاء
Fire performance depends on the complete wall, frame, seal and glazing construction, while the cleanroom-facing surfaces must remain flush and accessible for cleaning.
تطبيقات نموذجية
المعلمات الفنية
The ranges below describe common cleanroom fire-vision constructions; any declared fire performance applies only to the corresponding documented assembly.
| المواد الأساسية | Specialist clear fire-resistant glass protected by toughened safety-glass outer panes |
|---|---|
| سمك اللوحة | 30–70 mm glazing stack; typically 75–150 mm overall frame depth |
| العرض الفعال | 300–1200 mm clear viewing width for common single-light assemblies |
| الحد الأقصى الطول | 2400 mm overall window height, subject to the selected documented construction |
| الصلب يواجه سمك | 1.2–2.0 mm stainless or galvanized-steel subframe and liners |
| الكثافة الأساسية | Configuration-dependent multi-layer glass; typically 2500–3000 kg/m³ |
| الموصلية الحرارية | Approximately 0.3–1.0 W/(m·K), depending on the selected fire-glass composition |
| إنهاء السطح | Flush clear toughened outer glass with bonded ceramic-frit border and brushed stainless trim |
| نوع المشترك | Mechanically retained fire-glass assembly with fire-compatible seals and concealed subframe |
| التخصيص | متاح بناءً على التطبيق المقصود وبيئة التشغيل |
الخيارات المتاحة
Planning a Fire-Resistant Cleanroom Vision Panel specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية