Yangına Dayanıklı Temiz Oda Görüş Panel
- Specialist Fire-Glass Core
- Flush Protective Outer Panes
- Concealed Steel Subframe
- Assembly-Based Configuration
Ürün tanıtımı
The fire-resistant vision panel is built as a complete glazing-and-frame assembly rather than by substituting a pane into a standard cleanroom window. A specialist fire-glass layer is protected by toughened outer panes, retained within a steel or stainless-steel subframe and finished flush to the cleanroom surfaces. Glass type, edge cover, seal materials, opening size and wall construction are selected together so the supplied configuration can match the documented fire strategy without sacrificing cleanability.
Ana Özellikler
A concealed metal subframe supports the heavier glazing stack and maintains defined edge cover.
Screen-printed borders hide fire-compatible seals and mechanical retention from the room face.
Mullions and alternative glazing makeups allow the assembly to address different opening sizes and insulation needs.
Müşteri Ürün Sorunları
Fire performance depends on the complete wall, frame, seal and glazing construction, while the cleanroom-facing surfaces must remain flush and accessible for cleaning.
Tipik uygulamalar
Teknik parametreler
The ranges below describe common cleanroom fire-vision constructions; any declared fire performance applies only to the corresponding documented assembly.
| Temel malzemeler | Specialist clear fire-resistant glass protected by toughened safety-glass outer panes |
|---|---|
| Panel kalınlığı | 30–70 mm glazing stack; typically 75–150 mm overall frame depth |
| Effective Width (Etkili Genişlik) | 300–1200 mm clear viewing width for common single-light assemblies |
| Maksimum uzunluk | 2400 mm overall window height, subject to the selected documented construction |
| Çelik yüz yüze kalınlığı | 1.2–2.0 mm stainless or galvanized-steel subframe and liners |
| Core Density (Çekirdek Yoğunluğu) | Configuration-dependent multi-layer glass; typically 2500–3000 kg/m³ |
| Termal İletkenlik | Approximately 0.3–1.0 W/(m·K), depending on the selected fire-glass composition |
| Yüzey bitirme | Flush clear toughened outer glass with bonded ceramic-frit border and brushed stainless trim |
| Ortak tip | Mechanically retained fire-glass assembly with fire-compatible seals and concealed subframe |
| Customization (Özelleşme) | Kullanılan amaçlanan uygulama ve çalışma ortamına göre kullanılabilir |
Mevcut Seçenekler
Planning a Fire-Resistant Cleanroom Vision Panel specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca